Troubleshooting
Issues that may be easy to be mistaken for machine defects (continued)
Issue
No image is
displayed via
HDBaseT.
NETWORK
BRIDGE
function does
not work.
Schedule
function does
not work.
STANDBY
OUTPUT
(AUDIO OUT,
HDMI OUT,
MONITOR OUT)
does not work
with standby
mode.
(continued on next page)
LW502/LWU502 User's Manual - Operating Guide
020-001057-01 Rev. 1 (06-2016)
Cases not involving a machine defect
Check the LAN cable if it is CAT5e certified or higher.
Try to change the LAN cable.
If the LAN cable is connected with more than three
extension connectors, the transmission of 100 meters
may fail.
Check if the extension connector is compatible with
CAT5e.
All LAN cable and extension connector connected with
HDBaseT port must be CAT5e certified.
The NETWORK BRIDGE function is turned off.
Select NETWORK BRIDGE for COMMUNICATION TYPE
item in the OPTION - SERVICE - COMMUNICATION
menu.
The POWER SAVE function is working.
Select NORMAL for STANDBY MODE item in the
SETUP menu.
The internal clock has been reset.
Once you turn off the projector in the POWER SAVE
mode or the AC power, the current date and time setting
is reset.
Check the SCHEDULE setting for WIRELESS SETUP or
WIRED SETUP in the NETWORK menu.
Check if POWER SAVE is set in SETUP - STANDBY
MODE.
Set NORMAL in the menu above.
If the signal is not output yet, check if a desirable item is
set in SETUP - STANDBY OUTPUT.
Reference
page
90
72
72
122