Christie LX501 User Manual / Technical Manual

Projector christie
Hide thumbs Also See for LX501:

Advertisement

LX501/LW401/LWU421/
LX601i/LW551i/LWU501i
User Manual-Technical Guide
020-000503-02

Advertisement

Table of Contents
loading

Summary of Contents for Christie LX501

  • Page 1 LX501/LW401/LWU421/ LX601i/LW551i/LWU501i User Manual-Technical Guide 020-000503-02...
  • Page 3: Example Of Computer Signal

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i Projector LX501/LW401/LWU421/ LX601i/LW551i/LWU501i User Manual-Technical Guide User's Manual (detailed) - Operating Guide Technical Example of computer signal Resolution (H x V) H. frequency (kHz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480 31.5...
  • Page 4 *1) Supported except for HDMI input. *2) Only for LX501 and LX601i. *3) Supported except for LX501 and LX601i. *4) Only for LWU421 and LWU501i, but except for HDMI input. NOTE • Be sure to check jack type, signal level, timing and resolution before connecting this projector to a computer.
  • Page 5 LX501/LX601i/LW401/LW551i/LWU421/LWU501i Initial set signals Initial set signals The following signals are used for the initial settings. The signal timing of some computer models may be different. In such case, adjust the items V POSITION and H POSITION in the IMAGE menu.
  • Page 6: Monitor Out

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i Connection to the ports Connection to the ports NOTICE ►Use the cables with straight plugs, not L-shaped ones, as the input ports of the projector are recessed. ►Only the signal that is input from the COMPUTER IN1 or IN2 can be output from the MONITOR OUT port.
  • Page 7 LX501/LX601i/LW401/LW551i/LWU421/LWU501i Connection to the ports (continued) COMPUTER IN2 G/Y, B/Cb/Pb, R/Cr/Pr, BNC jack x5 <Computer signal> • Video signal: RGB separate, Analog, 0.7Vp-p, 75Ω terminated (positive) • H/V. sync. signal: TTL level (positive/negative) • Composite sync. signal: TTL level <Component video signal>...
  • Page 8 LX501/LX601i/LW401/LW551i/LWU421/LWU501i Connection to the ports (continued) COMPONENT Cb/Pb, Cr/Pr RCA jack x3 • Component video signal, Analog: -Y with composite sync, 1.0±0.1Vp-p, 75Ω terminated -Cb/Pb, 0.7±0.1Vp-p, 75Ω terminated -Cr/Pr, 0.7±0.1Vp-p 75Ω terminated • System: 480i@60, 480p@60, 576i@50, 720p@50/60, 1080i@50/60, 1080p@50/60...
  • Page 9 LX501/LX601i/LW401/LW551i/LWU421/LWU501i Connection to the ports (continued) AUDIO IN1, AUDIO IN2 Ø3.5 stereo mini jack • Analog, 500 mVrms, 47kΩ input impedance AUDIO IN3 AUDIO OUT RCA jack x2 RCA jack x2 • Analog, 500 mVrms, 47kΩ input impedance • Analog, 500 mVrms, 1kΩ output impedance...
  • Page 10: Remote Control

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i Connection to the ports (continued) RJ-45 jack * About the details of network communication, please refer to the Network Guide. Signal Signal Signal USB TYPE A USB TYPE B USB A type jack x2 USB B type jack Signal...
  • Page 11: To Input Scart Rgb Signal

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i Connection to the ports (continued) To input SCART RGB signal; RCA plugs SCART cable Audio R (plug) Audio L Video SCART connector (jack) To input SCART RGB signal to the projector, use a SCART to RCA cable. Connect the plugs refer to above ex. For more reference, please consult your dealer.
  • Page 12 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication RS-232C Communication When the projector connects to the computer by RS-232C communication, the projector can be controlled with RS-232C commands from the computer. For details of RS-232C commands, refer to RS-232C Communication / Network command table (&19).
  • Page 13 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication (continued) Communicaion settings 1. Protocol 19200bps, 8N1 2. Command format ("h" shows hexadecimal) Byte Number Command Header Data Header Data Setting Action Type code size flag code Packet Action <SET>Change setting to desired value [(cL)(cH)] (aL) (aH) 01h 00h (bL) (bH) (cL) (cH) by [(bL)(bH)].
  • Page 14: Response Code / Error Code

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication (continued) 3. Response code / Error code ("h" shows hexadecimal) (1) ACK reply: 06h When the projector receives the Set, Increment, Decrement or Execute command correctly, the projector changes the setting data for the specified item by [Type], and it returns the code.
  • Page 15: Command Control Via The Network

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i Command Control via the Network Command Control via the Network When the projector connects network, the projector can be controlled with RS- 232C commands from the computer with web browser. For details of RS-232C commands, refer to RS-232C Communication / Network command table (&19).
  • Page 16 LX501/LX601i/LW401/LW551i/LWU421/LWU501i Command Control via the Network Communicaion Port The following two ports are assigned for the command control. TCP #23 TCP #9715 Configure the following items form a web browser when command control is used. Port Settings Click the [Enable] check box to open [Network Port open Control Port1 (Port: 23)] to use TCP #23.
  • Page 17: Command Control Settings

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i Command Control via the Network Command control settings [TCP #23] 1. Command format Same as RS-232C communication, refer to RS-232C Communicaton command format. 2. Response code / Error code ("h" shows hexadecimal) Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4).
  • Page 18 LX501/LX601i/LW401/LW551i/LWU421/LWU501i Command Control via the Network 2. Response code / Error code ("h" shows hexadecimal) The connection ID is attached for the TCP#23's response / error codes are used. The connection ID is same as the sending command format. (1) ACK reply : 06h + ××h (××h : connection ID)
  • Page 19 LX501/LX601i/LW401/LW551i/LWU421/LWU501i Network Bridge Communication Network Bridge Communication This projector is equipped with NETWORK BRIDGE function. When the projector connects to the computer by wired or wireles LAN communicaton, an external device that is connected with this projector by RS- 232C communication can be controlled from the computer as a network terminal.
  • Page 20: Communication Settings

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i Network Bridge Communication Communication settings For communication setting, use the COMMUNICATION menu in the OPTION - SERVICE menu Item Condition BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps Data length 8 bit (fixed) PARITY NONE/ODD/EVEN Start bit 1 bit (fixed)
  • Page 21 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table RS-232C Communication / Network command table Command Data Names Operation Type Header Action Type Setting code Turn off BE EF 06 00 2A D3 01 00 00 60 00 00 Turn on BE EF...
  • Page 22 C1 26 02 00 15 23 00 00 * PbyP SWAP Execute BE EF 06 00 01 27 06 00 16 23 00 00 *) Supported except for LX501 and LX601i. (continued on next page) Technical Guide 020-000503-02 Rev. 1 (06-2012)
  • Page 23 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code NORMAL BE EF 06 00 23 F6 01 00 BA 30 00 00 CINEMA BE EF 06 00 B3 F7 01 00...
  • Page 24 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code BE EF 06 00 08 FE 02 00 90 30 00 00 User GAMMA Increment BE EF 06 00 6E FE 04 00...
  • Page 25 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code 1 HIGH BE EF 06 00 0B F5 01 00 B0 30 03 00 1 CUSTOM BE EF 06 00 CB F8...
  • Page 26 46 83 05 00 01 21 00 00 H POSITION Execute BE EF 06 00 1C D3 06 00 03 70 00 00 Reset *) Supported except for LX501 and LX601i. (continued on next page) Technical Guide 020-000503-02 Rev. 1 (06-2012)
  • Page 27: Auto Adjust Execute

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code BE EF 06 00 49 83 02 00 03 21 00 00 Increment BE EF 06 00 2F 83 04 00 03 21...
  • Page 28 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code AUTO BE EF 06 00 BA 77 01 00 13 22 00 00 VIDEO BE EF 06 00 2A 76 01 00...
  • Page 29 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code AUTO Execute BE EF 06 00 E5 D1 06 00 0D 20 00 00 KEYSTONE V EXECUTE BE EF 06 00 B9 D3...
  • Page 30 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code BE EF 06 00 31 97 02 00 41 21 00 00 * PERFECT FIT Increment BE EF 06 00 57 97...
  • Page 31 BE EF 06 00 DA B6 01 00 BF 20 FF 00 BE EF 06 00 19 F7 02 00 BF 20 00 00 *) Supported except for LX501 and LX601i. (continued on next page) Technical Guide 020-000503-02 Rev. 1 (06-2012)
  • Page 32 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code BE EF 06 00 CD CC 02 00 60 20 00 00 VOLUME - Increment...
  • Page 33 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code AUDIO IN1 BE EF 06 00 6E DC 01 00 30 20 01 00 AUDIO IN2...
  • Page 34 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code AUDIO IN1 BE EF 06 00 D6 DD 01 00 32 20 01 00 AUDIO IN2 BE EF 06 00 26 DD...
  • Page 35 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code BE EF 06 00 40 D7 02 00 16 30 00 00 MENU Increment BE EF 06 00 26 D7 04 00...
  • Page 36 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code BE EF 06 00 FA 62 01 00 00 37 00 00 BE EF 06 00 6A 63 01 00 00 37 01 00 C.
  • Page 37: Auto Power Off

    BE EF 06 00 0A 25 01 00 00 36 37 00 BE EF 06 00 09 33 02 00 00 36 00 00 *) Supported except for LX501 and LX601i. (continued on next page) Technical Guide 020-000503-02 Rev. 1 (06-2012)
  • Page 38 BE EF 06 00 4E 25 01 00 03 36 37 00 BE EF 06 00 4D 33 02 00 03 36 00 00 *) Supported except for LX501 and LX601i. (continued on next page) Technical Guide 020-000503-02 Rev. 1 (06-2012)
  • Page 39 LX501/LX601i/LW401/LW551i/LWU421/LWU501i RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code BE EF 06 00 FF 32 01 00 00 26 00 00 REMOTE BE EF 06 00 6F 33 01 00 00 26 01 00 RECEIV.
  • Page 40: Pjlink Command

    LX501/LX601i/LW401/LW551i/LWU421/LWU501i PJLink command PJLink command Commands Control Description Parameter or Response 0 = Standby POWR Power Contorol 1 = Power On 0 = Standby 1 = Power On POWR ? Power Status inquiry 2 = Cool Down 11 = COMPUTER IN1...
  • Page 41 LX501/LX601i/LW401/LW551i/LWU421/LWU501i PJLink command (continued) Commands Control Description Parameter or Response 1st byte: Refers to Fan error; one of 0 to 2 2nd byte: Refers to Lamp error; one of 0 to 2 3rd byte: Refers to Temptrature error; one of 0 to 2 4th byte: Refers to Cover error;...
  • Page 42 Corporate offi ces USA – Cypress ph: 714-236-8610 Canada – Kitchener ph: 519-744-8005 Worldwide offi ces United Kingdom Eastern Europe Singapore Japan ph: +44 118 977 8000 ph: +36 (0) 1 47 48 100 ph: +65 6877-8737 ph: 81-3-3599-7481 France Middle East Beijing South Korea...

This manual is also suitable for:

Lw401Lw551iLwu501iLwu421Lx601i

Table of Contents