DR
TRANSFER CASE - NV243 (Continued)
(5) Pull mainshaft assembly out of input gear,
mode sleeve, and case (Fig. 20).
Fig. 20 Remove Mainshaft
1 - FRONT CASE
2 - MAINSHAFT
(6) Remove mode fork, mode sleeve, and shift rail
as assembly (Fig. 21). Note which way the sleeve fits
in the fork (long side of sleeve goes to front).
Fig. 21 Mode Fork And Sleeve Removal
1 - MODE SLEEVE
2 - MODE FORK AND RAIL
(7) Remove range fork retaining ring.
(8) Remove range fork and hub as an assembly
(Fig. 22). Note fork position for installation reference.
(9) Remove shift sector (Fig. 23).
(10) Remove the shift sector o-ring (Fig. 24).
TRANSFER CASE - NV243
Fig. 22 Range Fork And Hub Removal
1 - RANGE HUB
2 - RANGE FORK
Fig. 23 Shift Sector Removal
1 - SHIFT SECTOR
Fig. 24 Remove the Shift Sector O-Ring
1 - TRANSFER CASE FRONT HOUSING
2 - SHIFT SECTOR O-RING
21 - 665