Fire Alarm Control Panel IQ8Control C/M
®
The esserbus
PLus cable is directly connected to the terminals on analog loop module (Part No. 804382 /
804382.10 / 804382.D0)
Example:
®
Fig. 58: esserbus
PLus cable terminal
Requirements components for the esserbus
Part No
Description
802426
Power supply module with selectable 27.5 V / 42 V analog loop voltage
27,5 V
or
42 V
804382 /
Analog loop module for esserbus
804382.10 /
804382.D0
max. 4 analog loop modules per Fire Alarm Control Panel
It is only permitted to connect suitable devices for the higher loop voltage 42 V e.g.
transponders or fire detectors with Part No. 80xxxx to the esserbus
Damage to the system !
®
esserbus
PLus must be installed with the appropriate loop devices. Mixed operation of standard
®
esserbus
and esserbus
loop voltage of 42 V. The loop devices compatible with esserbus
Part No. 80 xxxx.
1)
refer table chapter 5.1.3.
66
Analog loop module (Part No.804382 / 804382.10 / 804382.D0)
®
-PLus analog loop:
®
for esserbus
®
for esserbus
PLus
®
PLus connection.
®
PLus with one control panel is not possible because the higher analog
®
esserbus
PLus cable
1
terminal ⇒ Analog loop
module (Part No. 804382 /
804382.10 / 804382.D0)
The cable screen must be
connected to the mantle
terminal (panel housing)..
1)
®
PLus loop
®
PLus are indicated by the
FB 798951.GB0 / 01.09