19
E240 (The communication between DC CPU and IP-CPU has a fault.)
Cause
DIMM
Image processor
PCB
E243 (The communication between the control panel and the image
20
processor PCB has a fault.)
Cause
Connector
Harness
Control panel
Image processor
PCB
14-80
Step
Check
1
Turn off and then on the main
power. Is the problem corrected?
2
Disconnect and then connect
DIMM (J721, J722) on the image
processor PCB; then, turn on the
main power. Is the problem
corrected?
Step
Check
1
Turn off and then on the main
power. Is the problem corrected?
2
Is the connection between the
connector J710 on the image
processor PCB and the J901 on the
CPU PCB good?
3
Is there continuity on the harness
between the control panel PCU
PCB and the image processor PCB?
• J901-B12 and J710-B4
• J901-B14 and J710-B
4
Replace the control panel. Is the
problem corrected?
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Yes/No
Action
YES
End.
YES
End.
NO
If the problem still
occurs after replacement
of the DIMM, replace
the image processor
PCB.
Yes/No
Action
YES
End.
NO
Correct the connection.
NO
Replace the harness.
YES
End.
NO
Replace the image
processor PCB.