CHAPTER 14 TROUBLESHOOTING
3
E002, E003 (The Fixing Temperature Error message turns on.)
Cause
Thermistor
Wiring
Thermal switch
Relay
DC controller
PCB
Image processor
PCB
14-58
Step
1
Clear the error in service mode.
2
When the machine has warmed up,
does any of the following apply?
• The fixing heater fails to
operate.
• E000 is indicated.
3
Wait until the fixing assembly has
cooled sufficiently; then,
disconnect J426, and measure the
resistance of the thermistor. Is the
reading as follows?
J426 (white harness; TH1): about 0 Ω
J426 (black harness; TH2): about 0 Ω
4
Is the wiring from the connector
J114 on the DC controller PCB to
the thermistor good?
4
Replace the thermal switch. Is the
problem corrected?
5
Replace the relay. Is the problem
corrected?
6
Replace the DC controller PCB. Is
the problem corrected?
7
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Check
Yes/No
Action
YES
See the appropriate
descriptions.
YES
Replace the thermistor
unit.
NO
Correct the wiring.
YES
End.
YES
End.
YES
End.
NO
Replace the image
processor PCB.