CHAPTER 14 TROUBLESHOOTING
Notation
name
Meter probe
Service mode
Check (Normal if
described.)
Display reading
Meter reading (approx.)
Notation
name
Meter probe
Service mode
Check (Normal if
described.)
Display reading
Meter reading (approx.)
14-32
PS14
Front cover open/
closed sensor (PS14S)
J102-A11
P003-bit4
While in standby, open
the front cover.
When the
When the
front
front
cover is
cover is
open,
closed,
1
0
5 V
0 V
PS40
Fixing assembly outlet
sensor (PS40S)
J114-A2
P004-bit9
While in standby, push
the lever on the fixing
assembly outlet
assembly.
When the
When the
lever is
lever is
pushed,
not
pushed,
1
0
0 V
5 V
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
PS18
Cassette 1 pick-up
sensor (PS18S)
J108-A17
P004-bit0
While in standby, slide
out the cassette, and
insert paper between
the pick-up rollers.
When
When
paper is
paper is
inserted,
not
inserted,
1
0
5 V
0 V
PS19
Cassette 1 pick-up
sensor (PS19S)
J108-A18
P004-bit1
While in standby, slide
out the cassette, and
insert paper between
pick-up rollers.
When
When
paper is
paper is
inserted,
not
inserted,
1
0
5 V
0 V