CHAPTER 11 SYSTEM INTEGRATION
4) Slide SW702 to '2' (OFF).
Figure 11-315
5) Free the harness guide of the scanner from
the hooks.
Harness guide
Figure 11-316
11-12
SW702
Hooks
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
6) Disconnect the connector shown in the
figure.
7) Push the boss on the locking support
shown in the figure, and detach the board
as if to pull it off the locking support.
Scanner cable
Battery board
Locking support
Figure 11-317
2. Mounting the Battery Board
1) Mount the battery board securely to the
locking support, being careful so that it
will not be over the IP cover or the metal
plate.
2) After installing the battery board, slide
SW702 to '3' (ON).
3) Mount the harness guide, small cover,
copyboard glass, and copyboard glass
retainer (right).
Connector
Push
the claw.