Primary Charging Roller Cleaning Solenoid - Canon GP405 Service Manual

Hide thumbs Also See for GP405:
Table of Contents

Advertisement

E. Primary Charging Roller
Cleaning Solenoid
1. Removing the Primary Charging
Roller Cleaning Solenoid
1) Remove the following parts:
Drum unit
Developing assembly
Rear cover
Flywheel
Power cord mount
Composite power supply PCB
DC controller PCB
Low-voltage PCB
Accessories power supply PCB
Scanner cooling fan assembly
Main drive unit
Registration clutch
2) Free the harness, and remove the two
screws [1]; then, detach the harness guide
[2].
[2]
Figure 6-405
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[1]
[1]
CHAPTER 6 IMAGE FORMATION SYSTEM
3) Remove the two screws [3], and detach
the primary charging roller cleaning
solenoid unit [4].
Figure 6-406
4) Disconnect the connector [5], and remove
the two screws [6]; then, detach the

primary charging roller cleaning solenoid

[7].
[5]
[7]
Figure 6-407
2. Adjusting the Position
Adjust the position of the primary
charging roller cleaning solenoid (SL1) so that
the length shown in Figure 6-408 is 4.0 ±0.2
mm.
4.0 ± 0.2mm
Figure 6-408
[3]
[4]
[6]
6-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp335

Table of Contents