5) Close the delivery assembly, and shift the
delivery assembly lower cover to remove.
Caution:
The delivery assembly lower cover
cannot be removed unless the delivery
assembly is closed. Be sure to free the
hook, and then close the lever assembly.
6) Disconnect the connector [5].
7) Open the delivery assembly, and remove
the screw [7]; then, detach the cable from
the copier (both rear and front).
[6]
[7]
Figure 7-237
8) Pull out the spacer [8] from the right side
of the delivery assembly.
9) Release the bushing [9] by shifting it to
the left.
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[5]
CHAPTER 7 PICK-UP/FEEDING SYSTEM
[8]
Figure 7-238
10) Shift the delivery assembly to the right,
and detach its left and then its right.
•
When mounting the delivery assembly
connector cover 9, be sure that it will not
interfere with the spring 10 of the lower
feeding assembly.
[9]
Figure 7-238-1
1
Detach.
Shift.
2
[9]
[10]
7-63