Msi/Plessey Minimum Label Length - Datalogic Magellan 8500 Product Reference Manual

Hide thumbs Also See for Magellan 8500:
Table of Contents

Advertisement

MSI/Plessey Minimum Label Length

NOTE
6-262
This feature specifies the minimum allowable length of an MSI/Plessey
label.
Length in this case includes check and data characters, but does not
include start, stop or full ASCII shift characters. This applies when MSI/
Plessey Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label
length.
To set this feature:
1. Scan the SWITCH barcode.
2. Scan the barcode, SET MSI/PLESSEY MINIMUM LABEL
LENGTH below. You'll need to cover any unused barcodes on
this and the facing page to ensure that the scanner reads only the
barcode you intend to scan.
3. Scan the appropriate digits from the keypad in
represent the desired minimum label length. The selectable range
for this option is 4 to 16. Pad all single digit numbers with a lead-
ing zero to yield a two-digit entry (04-16).
4. Complete the programming sequence by scanning the SWITCH
barcode.
SET MSI/PLESSEY MINIMUM LABEL LENGTH
Appendix C
Magellan
8500 Scanner
®
that