Stepper Axes Outputs 4-5 (Nes002-503 Only); Power Inputs - Baldor NextMove ES Installation Manual

Motion controller
Table of Contents

Advertisement

5.2.10 Stepper axes outputs 4-5 (NES002-503 only)

Stepper axes outputs 4-5 are not isolated or driven by the backplane. See section 4.4.2.2 for
electrical specifications of step and direction outputs 4 and 5.

5.2.11 Power inputs

See section 3.1.4 for power requirements.
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
5-12 Backplanes
Location X5
Mating connector: Weidmüller Omnimate BL 3.5/5
5
Pin Name
5 DGND
1
4 DOUT11
3 DOUT10
2 DOUT9
1 DOUT8
Location X1
Mating connector: Weidmüller Omnimate BL 3.5/5
5
Pin Name
5 DGND
1
4 DGND
3 +5V
2
-12V
1 +12V
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Fax: (973) 335-1661 • www.servosystems.com
Description
Digital ground
Direction output 5
Step (pulse) output 5
Direction output 4
Step (pulse) output 4
Description
Digital ground
Digital ground
+5 V input
-12 V input
+12 V input
www.baldormotion.com
96-pin
connector
a3
c22
c16
b13
a13
96-pin
connector
a3
a3
a1
a31
a29
MN1928