Digital Input/Output Configuration; Digital Input Configuration - Baldor NextMove ES Installation Manual

Motion controller
Table of Contents

Advertisement

6.10 Digital input/output configuration

The Digital I/O window can be used to setup other digital inputs and outputs.

6.10.1 Digital input configuration

The Digital Inputs tab allows you to define how each digital input will be triggered, and if it
should be assigned to a special purpose function such as a Home or Limit input. In the
following example, digital input 1 will be set to trigger on an active low input, and allocated to
the forward limit input of axis 0:
1. In the Toolbox, click the Digital I/O icon.
2. At the bottom of the Digital I/O screen, click
the Digital Inputs tab.
The left of the screen shows a column of
yellow icons - High, Low, Rising, Falling
and Rise/Fall. These describe how the
input will be triggered.
3. Drag the Low icon
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
6-30 Operation
onto the IN1 icon
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Fax: (973) 335-1661 • www.servosystems.com
. This will setup IN1 to respond to a low input.
www.baldormotion.com
MN1928

Advertisement

Table of Contents
loading

Table of Contents