8.1.6 Digital outputs - general purpose (non-isolated)

This specification is for the NextMove ES card when used separately or in conjunction with the
optional non-isolating backplane BPL010-501:
Description
Load supply voltage
(maximum)
Output current
Max. sink per output, one output on
Max. sink per output, all outputs on
Update interval

8.1.7 Digital outputs - general purpose (opto-isolated)

This specification is for the optional opto-isolating backplanes BPL010-502 or BPL010-503,
when used in conjunction with the NextMove ES card.
Description
USR V+ supply voltage
Output current (BPL010-502)
Max. source per output, one output on
Max. source per output, all outputs on
Output current (BPL010-503)
Max. sink per output, one output on
Max. sink per output, all outputs on
Update interval
Switching time

8.1.8 Digital output - error output (non-isolated)

This specification is for the NextMove ES card when used separately or in conjunction with the
optional non-isolating backplane BPL010-501:
Description
Output voltage
Output current
(maximum)
Update interval
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
MN1928
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Maximum
Minimum
No load on output
With 7 mA or greater load
Fax: (973) 335-1661 • www.servosystems.com
Unit
V
mA
DOUT0-7
500
150
Unit
VDC
mA
DOUT0-7
350
75
mA
DOUT0-7
500
150
Unit
V
mA
www.baldormotion.com
Value
50
DOUT8-11
400
50
Immediate
Value
30 V
12 V
DOUT8-11
400
50
DOUT8-11
400
50
Immediate
100 ms
10 μs
Value
5
100
Immediate
Specifications 8-3

Advertisement

Table of Contents
loading