Baldor NextMove ES Installation Manual page 65

Motion controller
Table of Contents

Advertisement

5.3.5 Digital inputs 16-19
The BPL010-502 and BPL010-503 opto-isolating cards use different input configurations.
Sections 5.3.5.1 and 5.3.5.2 describe the two input types.
5.3.5.1 BPL010-502 - Active high inputs
The user power supply connection USR GND is common to all inputs. To activate an input, a
voltage must be applied that is sufficient to cause at least 5 mA in the input circuit. To ensure
that an input becomes inactive, the current must be less than 1 mA. The internal pull-up
resistor on the NextMove ES allows the input to be left floating when inactive or not being
used.
User
supply
24 V
User
USR GND
supply
GND
Figure 31 - Digital input circuit (DIN16) with 'active high' inputs
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
5-22 Backplanes
Location
X6
10
Mating connector: Weidmüller Omnimate BL 3.5/10
Pin
Name
10
Shield
9
USR GND
8
USR GND
7
USR V+
1
6
USR V+
5
-
4
DIN19
3
DIN18
2
DIN17
1
DIN16
Backplane & opto-isolator card
'X6'
DIN16
1
8
TLP521-4
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Fax: (973) 335-1661 • www.servosystems.com
Description
Shield connection
Customer power supply ground
Customer power supply ground
Customer power supply
Customer power supply
(NC)
Digital input DIN19
Digital input DIN18
Digital input DIN17
Digital input DIN16
96
2k2
pin
connector
www.baldormotion.com
NextMove ES
96-pin
connector
a32
c12
b26
c25
c24
c11
NextMove ES
+5 V
10k
74AHCT14
MN1928
Mint
INX(16)
GND

Advertisement