Multidrop Using Rs485 / Rs422 - Baldor NextMove ES Installation Manual

Motion controller
Table of Contents

Advertisement

4.5.6 Multidrop using RS485 / RS422

Multidrop systems allow one device to act as a 'network master', controlling and interacting
with the other (slave) devices on the network. The network master can be a controller such as
NextMove ES, a host application such as Mint WorkBench (or other custom application), or a
programmable logic controller (PLC). RS422 may be used for multi-drop applications as
shown in Figure 16. Four-wire RS485 may be used for single point-to-point applications
involving only one Baldor controller. If firmware is updated over RS485/RS422, it can only be
downloaded to the controller that was chosen in the Select Controller dialog in Mint
WorkBench.
Network
master
TX+
TX-
RX+
RX-
DGND
Master and final slave are
shown with terminating
resistors, T
120 Ω.
Jumper JP2 connects an
internal 120 Ω terminating
resistor. JP2 is located just
behind the serial connector on
the NextMove ES card.
Each transmit/receive (TX/RX) network requires a termination resistor at the final RX
connection, but intermediate devices must not be fitted with termination resistors. An exception
is where repeaters are being used which may correctly contain termination resistors.
Termination resistors are used to match the impedance of the load to the impedance of the
transmission line (cable) being used. Unmatched impedance causes the transmitted signal to
not be fully absorbed by the load. This causes a portion of the signal to be reflected back into
the transmission line as noise. If the source impedance, transmission line impedance, and
load impedance are all equal, the reflections (noise) are eliminated. Termination resistors
increase the load current and sometimes change the bias requirements and increase the
complexity of the system.
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
MN1928
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Twisted pairs
T
R
, typical value
R
Figure 16 - 4-wire RS422 multi-drop connections
Fax: (973) 335-1661 • www.servosystems.com
www.baldormotion.com
Network slave
RX+
RX-
TX+
TX-
DGND
Network slave
T
R
RX+
RX-
TX+
TX-
DGND
Connect overall shield
to connector backshell.
Input / Output 4-19

Advertisement

Table of Contents
loading

Table of Contents