Digital I/O; Digital Inputs - Baldor NextMove ES Installation Manual

Motion controller
Table of Contents

Advertisement

4.4 Digital I/O

The NextMove ES provides:
20 general purpose digital inputs.
H
12 general purpose digital outputs.
H

4.4.1 Digital inputs

The digital inputs are available across a range of pins, as shown in section 4.2.1. All digital
inputs have a common specification:
5 V digital inputs with internal pull-up resistors. Can also be assigned to special purpose
H
functions such as Home, Limit, Stop and Error inputs.
Sampling frequency: 1 kHz.
H
Do not connect 24 V signals to the digital inputs.
CAUTION
These unprotected inputs are connected directly to TTL compatible 74AHCT14 devices. If an
input is configured as edge triggered, the triggering pulse must have a duration of at least 1 ms
(one software scan) to guarantee acceptance by Mint. The use of shielded cable for inputs is
recommended.
4.4.1.1 General purpose inputs
The general purpose digital inputs DIN0 - DIN19 can be shared between axes, and are
programmable in Mint (using a range of keywords beginning with the letters INPUT... ) to
determine their active level and if they should be edge triggered. The state of individual inputs
can be read directly using the INX keyword. See the Mint help file.
A general purpose digital input can be assigned to a special purpose function such as a home,
limit, stop or error input. See the keywords HOMEINPUT, LIMITFORWARDINPUT,
LIMITREVERSEINPUT, STOPINPUT, and ERRORINPUT in the Mint help file.
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
4-8 Input / Output
NextMove ES
+5V
DIN0
c21
DGND
a3
Figure 7 - General purpose digital input - DIN0 shown
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Fax: (973) 335-1661 • www.servosystems.com
Mint
74AHCT14
INX(0)
GND
www.baldormotion.com