8 = Outputs (cont'd)

8 Security

The Security output type is instantly activated by the opening of Security zones
in a set or unset state. The output latches on until a valid code is entered. The
Security output is not subject to Re-arm or Bell Delay.

9 Confirm

The Confirm output type is used to give confirmation of an Intruder type alarm.
The Confirm output is only triggered by the following zone types: Exit/Entry,
Intruder, Dual and Security. After the first activation of one of these zone types
the Intruder outputs will activate; following this another activation of one of
these zone types (on a different zone) will cause the Confirm output to activate.

10 Horn

The Horn output type is activated by any event that activates the keypad horn,
that is: keypad zone chimes, see
3: GALAXY KEYPADS; Keypad Operation; Star Key
following zone types Intruder, Fire, PA, Dual, Security, also Final and Exit/Entry
zone types (activating Exit Time and Entry Time countdowns respectively).

11 Medical

The Medical output type is activated by holding down the Star (Ö) and 5 keys on
the keypad to cause a Medical alarm. Once the Medical output has been activated
MEDICAL
the word
keypad is pressed to acknowledge the alarm. A valid User Code or the Engineer
Code must be entered to cancel the alarm. For more information on the star key
functions see
Section 3: GALAXY KEYPADS; Keypad Operation; Star Key
The Medical output is also activated by the activation of a Link A zone type that
has been assigned the Medical (M) SIA mnemonic.

12 AC Fail

The AC Fail output type is activated in the event of a mains power failure. It is
restored to the de-active state when the a.c. mains supply returns.

13 Link A

The Link A output type is activated when a zone of type Link A is open. For more
information see
Option 7 – Zones; 13 Link A
Functional Programming Options.

14 Link B

The Link B output type is activated when a zone of type Link B is open. For more
information see
Option 7 – Zones; 14 Link B
Functional Programming Options.
OPTION 2: CHIME
appears on the keypad display until one of the buttons on the
; Medical alarms, see
; activation of any of the
and Table 5.12 Link A and B
and Table 5.12 Link A and B
76