13 = Communications 2 (cont'd)

8 Conf Aftr Ent

This option determines if confirmed alarms can be signalled after the start of an
entry procedure.

9 Disable Kpads

This option determines whether keypad unsetting is permissable (required for
fob controlled installations).
The keypads will be able to function normally during set and entry, regardless
of this option, for part sets in which intruder alarms are not reportable.

0 Never

The keypad is always active

1 Entry Only

The keypad will not unset during the entry time only

Set or Entry

Keypads will be disabled when the panel is set, including entry time.

10 ET Starts CT

This option enables or disables Timeouts alarms from starting the confirmed
alarms.

11 Exit RT Conf

This option determines if EXIT type zones can contribute to confirmed alarms.

1 Always

They will contribute anytime they are activated in an alarm condition (except
during an entry).

2 Before Entry

They can only contribute before entry timer has been started (i.e. they will not
contribute even after the entry time has expired.

12 Repeat 1st ZN

This allows the confirm timer to be restarted, if the same zone is activated again
during the confirm time, and a confirmed alarm has not yet occured.

1 Leave Confirm

Confirm timer is not started

2 Restart C/Tim

Confirm timer is restarted upon repeated activation of the first to alarm zone.