13 = Communications 2 (cont'd)
8 Conf Aftr Ent
This option determines if confirmed alarms can be signalled after the start of an
entry procedure.
9 Disable Kpads
This option determines whether keypad unsetting is permissable (required for
fob controlled installations).
The keypads will be able to function normally during set and entry, regardless
of this option, for part sets in which intruder alarms are not reportable.
0 Never
The keypad is always active
1 Entry Only
The keypad will not unset during the entry time only
Set or Entry
Keypads will be disabled when the panel is set, including entry time.
10 ET Starts CT
This option enables or disables Timeouts alarms from starting the confirmed
alarms.
11 Exit RT Conf
This option determines if EXIT type zones can contribute to confirmed alarms.
1 Always
They will contribute anytime they are activated in an alarm condition (except
during an entry).
2 Before Entry
They can only contribute before entry timer has been started (i.e. they will not
contribute even after the entry time has expired.
12 Repeat 1st ZN
This allows the confirm timer to be restarted, if the same zone is activated again
during the confirm time, and a confirmed alarm has not yet occured.
1 Leave Confirm
Confirm timer is not started
2 Restart C/Tim
Confirm timer is restarted upon repeated activation of the first to alarm zone.