Installation Recommendations

System Installation and Wiring

The installation and wiring must be performed by a competent engineer. For
permanently connected equipment a readily accessible disconnect device must
be incorporated into the fixed wiring with contact separation of at least 3 mm on
each pole. The Galaxy control panel must be connected to the a.c. mains supply
(230 V (+10%, – 8%) a.c. 50 Hz) via a fused connection outlet.
The fuse in the mains outlet must not exceed 3 A.
Route the mains cable through the hole on the right hand side of the enclosure
base. Securely anchor the cable to the enclosure base using the cable tie as
shown in Figure 1.5 Securing the Mains Cable to the Panel.
To Transformer
Figure 1.5 Securing the Mains Cable to the Panel.
Secure the enclosure base to the wall using three 1.5" No. 8 round-head steel
screws through the holes provided.
The mains cable used must be a three core type (with green/yellow earth
insulation) of adequate current carrying capacity.
Note: The mains cable must satisfy the requirements stated in BS6500.
Connect the mains cable to the mains terminal block as follows:
• blue wire to the terminal marked N (Neutral)
• green/yellow wire to the terminal marked (Earth)
• brown wire to the terminal marked L (Live)
Note: No other connections to the mains connector are permitted.
All wiring must be in accordance with the latest edition of the IEE Wiring
Regulations (Regulations for Electrical Installations), see also BS7671.
Once all zone and module wiring has been completed replace the lid of the
enclosure and screw the lid to the base with the screws provided.

Stand-by Battery

The Galaxy 16/16 plus can accommodate a 15 Ahr stand-by battery in the
control panel enclosure. Ensure that the battery connector leads on the control
panel PCB are connected to the correct terminals on the battery.