Expiry Warning
During the last 25% of the programmed exit time the keypad buzzers and entry/
exit horns begin to pulse rapidly, indicating that time is running short.
Entry Time
The system begins the unsetting routine whenever a Final or Entry zone
activates. The keypad buzzers and Entry/Exit horns pulse slowly indicating that
the entry time countdown has started. The user must go directly to the keypad,
using the agreed entry route, and unset the system before the entry time
expires. When 75% of the entry time has elapsed the keypad buzzers and Entry/
Exit horns pulse rapidly, indicating that time is running short.
Entry Time-Out
The default operation for the entry time expiring before a valid user code is
entered is that a full alarm occurs. This can be altered by programming an Abort
time, for more information see Section
eters; 06 User Options; Abort and Star Abort
Straying From the Entry Route
The default operation for a user straying from the agreed entry route and
activates a zone in a protected area during the entry routine is that a full alarm
occurs. This can be altered by programming an Abort time, for more information
see Section
5: MENU OPTIONS; Option 6 – Parameters; 06 User Options;
Abort and Star Abort
Power Failures while the System is Set
If there is a power failure (both a.c. mains and stand-by battery) then when
power is restored to the system the system attempts to return to the set status,
full or part, that it was in prior to the power failure.
The system begins the setting procedure. If there are no unomitted zones open
the panel starts a 20 second exit time at the end of which the appropriate
(previously set) parts re-arm.
Note: If any unomitted zones are open then the system attempts to re-arm but
will be unable to do so until all unomitted zones in the appropriate
(previously set) parts are closed.
2 OMIT
000000000
000000000
000000000
000000000
000000000
Figure 4.8 Omitted Zones.
5: MENU OPTIONS; Option 6 – Param-
.
Setting Features
060
.