To cancel the cold start press the esc key.
To delete the system programming press the ent key. The warning message
remains on the keypad for a few seconds then returns to the normal unset mode
banner. The system is now at the default settings for all options.

10 Remote Reset

This parameter allows the Remote Reset facility to be switched on and off.
Press key 1 = On or 0 = Off. The default setting is 0 = OFF.
The Galaxy 16/16 plus operates with the Technistore remote reset facility. After
an alarm occurs with the Remote Reset enabled, the user cannot reset the
system until the correct Technistore code is entered. A random five digit
number is generated by the control panel and displayed on the keypad. This
number must be quoted to the Monitoring Station. The Monitoring Station
returns the decoded Technistore reset number that resets the system when
entered at the keypad.
Notes: The Engineer Code can be used to reset the system. Entering, then exiting,
Engineer Mode returns the system to the Unset Banner.
This option is affected by
If Remote Reset is enabled Tamper alarms always require to be reset by either
the Engineer Code or a Technistore reset. The intruder and PA Reset param-
eters must be enabled for Intruder and PA alarms to require a Technistore reset,
see
07 Reset
.

11 Remote Version

This parameter determines the Monitoring Station decoder version (000 to 255)
of the Technistore system. The Monitoring Station allocates the Remote
Version number. The engineer assigns the allocated number to this parameter.

12 Banner Top

This parameter is used by the engineer to modify the top line of the keypad
Unset Banner display.
On selecting Banner Top the current banner text appears on the top line of the
display; if the top line is blank this means that the top line of the Unset Banner
is set to default, that is, panel type and software version. On the bottom line a
selection of the range of available alphanumeric characters are displayed; in the
middle of the characters there is an underscore. Press the A or B keys to scroll
through the alphanumeric characters. Pressing the ent key causes whichever
character is above the underscore to be added to the line of text. Pressing the
Ö key will erase characters from the line of text, one character per press. To
accept whatever is displayed on the text line as the top line of the Unset Banner
press the esc key.
Note: If the text line is blanked, then the top line of the Unset Banner displays the
default text, that is, panel variant and software version.
6 = Parameters (cont'd)
11 Remote Version
65
.