Silent Setting

The 0 key can be programmed to act as a terminator for both the full and part
setting procedures. This allows the setting to be initiated and terminated from a
keypad. When the 0 key is used to terminate the setting, the Horn output and
keypad buzzers emit exit tones but do not emit confirmation tones. The keypad
briefly displays the message
Refer to
Section 5: MENU OPTIONS; Option – 6 Parameters; 6 User Options;
.
6 Instant Key–0

Cancelling the Setting

The full and part setting routines can be aborted by pressing the esc key
during the exit time; this must be on the same keypad used to initiate the setting
procedure.

Unsetting the System (Code + ent Key)

Only users with the Unset Access attribute enabled can fully or partly unset
the system. Refer to
To unset the system the user must enter their code then press ent. This unsets
all parts assigned to the user.

Part Unsetting (Code + B Key)

A full or part set system can be part unset by entering the user code which
displays the unsetting options, see Figure 4.6 Unsetting Options. To select part
unset press the B key, the keypad displays the set status of those parts of the
system assigned to the user code, see Figure 4.3 Part Set Selection.
• Those parts that are
• To alter the set/unset status of a part press the number corresponding
to that part, that is, pressing the 1 key will toggle the set status of part 1.
• The equals sign indicates that what is displayed beside the part number
is the current status of the part, that is, P1=ON denotes that part 1 is
currently set. Pressing the 1 key will cause the display to read P1TOFF,
this indicates a transitional state where part 1 is provisionally
programmed as unset.
• The parts will not unset until the ent key is pressed to accept the
programming.
SYSTEM IS SET
Section 5: MENU OPTIONS; Option 4 – Codes
A=SET B=PART
ENT =UNS ET
Figure 4.6 Unsetting Options.
ON
are set, those that are
Silent Setting
before the display clears.
OFF
are unset.