Keyswitch Setting Options
Engineer Unsetting
The engineer can only unset a system that was set using the engineer code.
The engineer code can not be used to unset a system that was set by a user
code.
Keyswitch Setting Options
Zones programmed as Keyswitch can be used to set and unset the system. The
Keyswitch zone assumes the user attributes of one of user codes 1, 2 or 3 —
the user code is assigned to the zone in
witch zone, depending on the attributes of the user code assigned to it, can be
used to: reset alarms; cancel alarms; full set and unset the system; part set and
part unset the system; set only or unset only.
Refer to
:
Section 5
and
witches
Option 7
Setting and Unsetting the System with a Keyswitch
A keyswitch with a latching operation, 1 kΩ to 2 kΩ to set, 2 kΩ to 1 kΩ to
unset, can be used to set the system, see
Zones; Wiring Keyswitches
The Keyswitch starts the setting procedure of each of the parts assigned to the
assigned user code. At the end of the exit time, or when a Final or Push-to-Set
zone terminates the setting procedure, the Horn output and the keypad buzzers
become silent for four seconds, then emit two long tones to confirm that the
system is set.
The transition from 2 kΩ to 1 kΩ unsets all parts assigned to a keyswitch with
the unset attribute enabled.
Setting Features
Exit Time
Once the setting routine starts, the keypad buzzers and control panel entry/exit
horns (if fitted) emit a continuous tone. When the system setting routine is
initiated from the keypad, the display indicates the time remaining, in seconds,
before the system sets.
Omitted Zones
If any zones are omitted when the system starts setting, this is indicated on the
keypad. The keypad indicates how many zones are omitted.
;
MENU OPTIONS
Option 4
–
;
Zones
4 Keyswitch
.
TIMED
000000000
000000000
000000000
000000000
000000000
Figure 4.7 Exit Time.
42
Menu Option 7 – Zones
–
Codes; Codes and Keys-
.
Section 1: System Architecture;
060
. The Keys-