Part Setting The System (The B Key) - ADEMCO Galaxy 16 Engineer's Manual

8–16 zone security control panel
Table of Contents

Advertisement

Part Setting the System (The B Key)

To part set the system the user must first enter their user code then press the B
key. The keypad then displays the set status of those parts of the system
assigned to the user code, see Figure 4.3 Part Set Selection.
SELECT
• Those parts that are
• To alter the set/unset status of a part press the number corresponding
to that part, that is, pressing the 1 key will toggle the set status of part 1
between set/unset.
• The equals sign indicates that what is displayed beside the part number
is the current status of the part, that is,
currently set. Pressing the 1 key will cause the display to read
this indicates a transitional state where part 1 is provisionally
programmed as unset.
• The actual set status of the part will not be altered until the ent key is
pressed to accept the programming. The keypad then displays which
parts are setting along with the part set exit-time countdown.
• At the end of the exit-time, or when the closing of a Final or Push-to-Set
zone terminates the setting procedure, the Horn outputs and the keypad
buzzers become silent for four seconds and the countdown blocks on
the keypad display all clear. The keypad buzzers and horn outputs emit
two long tones to confirm that the system is set. On the keypad the
SYSTEM IS SET
message
display clears.
This sequence is illustrated in Figure 4.4 Part Setting Routine for Group 3 Only.
Note: If the Instant Key 0 option is used to terminate the setting then no
conformation beeps are given. See
Parameters; 6 User Options; 6 Instant Key 0
The following points should be noted about Part Setting:
• If the user code has all parts assigned it can be used to set all parts, this
is a full set of the system.
• If the user code does not have all parts assigned to it and the parts not
assigned to it are set then the code can be used to full set the system.
• If the user code does not have all parts assigned to it and the parts not
assigned to it are unset then the code can only be used to part set the
system.
Part Setting the System
Part Set selections for user code
P1 = OFF
with Parts 1 and 3 assigned.
P3T T T T T ON
Part 1 is unset, Part 3 provisionally
programmed as set
Figure 4.3 Part Set Selection.
ON
are set, those that are
appears briefly. The parts are now set and the
39
OFF
are unset.
P1=ON
denotes that part 1 is
Section 5: MENU OPTIONS: 6 –
for details.
P1TOFF
,

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF