Option 3 - Walk

The engineer function and user function of this option are identical. The Walk
option is used to walk test selected zones on the system.
When the Walk option is selected zone 01 is displayed. All zones default to
disabled (excluded from the walk test), when a zone is disabled from the walk
test the top line of the keypad display shows a hollow square next to the zone
number and the bottom line reads #, xx = TEST, where xx is the zone number.
A zone is included in the walk test when a filled square appears next to the zone
number and TEST appears on the bottom line of the display. This is illustrated
in Figure 5.6 Walk Statuses.
Press the A or B key to view and select other zones. Pressing the zone number
keys (01 - 16) directly toggles the test status of the corresponding zones. Once
the desired zones have been selected press ent to exit the menu option and
start the test or esc to exit and cancel the test.
INTRUDER
04
#, 04 = TEST
(a) Zone 04 Walk Test disabled
All zones are eligible for inclusion in the walk test.
During the test the circuit response (debounce) time is reduced to 50 ms, on all
zones included in the Walk test, for the duration of the test, to facilitate the
detection of loose connections or damaged wiring. When the zones to be
tested have been selected, press the ent key to start the Walk Test. The
keypad immediately displays how many of the currently selected zones are
open. Each zone tested activates the keypad buzzers and horn output on the
panel and is recorded in the event log.
When the Walk test is complete the keypad displays how many of the selected
zones are currently open.
Press the # key to display how many of the selected zones were registered as
tested, the A or B key can be used to scroll through the zone details
(Descripter, number and zone type.
Pressing the hash key again displays all the zones that were registered during
the test.
Note: Zones 10 to 16 are labelled A to G.
The Walk option can be manually terminated by pressing the esc key. The
Walk test automatically terminates if all the selected zones remain inactive for 20
minutes.
Note: The zones can also be tested using the Soak test option. See Menu Option
7 - Zones; Zones and Soak Test.
# or 04 to toggle
Walk Test status
Figure 5.6 Walk Statuses