Interrupted Setting
PART
time countdown
SYSTEM IS SET
System Set confirmation
Figure 4.4 Part Setting Routine for Group 3 Only.

Interrupted Setting (Full or Part)

If the exit time countdown is interrupted by a zone opening then: the zone
number, type and descriptor will be displayed; the Horn outputs will activate;
and the keypad buzzers will beep rapidly until the zone is closed.
If the exit time countdown is interrupted by more than one zone opening then
the keypad will display the number of zones open and prompt the user to view
the zone number, type and descriptor using the A and B keys; the Horn
outputs activate and the keypad buzzers beep rapidly until all zones are closed.
Closing all zones will cause the setting routine to restart.
See Figure 4.5 Interrupted Setting Messages.
Zone No. Zone Type.
04 I NT RUDER
BAKERY
Zone 04 open during exit
time countdown.
Figure 4.5 Interrupted Setting Messages.

Setting with Omitted Zones

The system may be set with zones omitted (bypassed), this means that those
zones are not monitored during the set period and will not cause the system to
go into alarm. For more information on omitting zones and setting with zones
omitted see
Section 5: Menu Options; Option 1 Omit
3
060
000000000
000000000
000000000
000000000
000000000
(a)
Part set exit
(c)
Zone Descriptor.
(a)
40
PART
3
00000000000000000
00000000000000000
00000000000000000
00000000000000000
00000000000000000
(b)
Countdown terminated
(d)
Screen goes blank
02 O PEN
[ <] , [ >] T O VI EW
(b)
Two zones open during
exit time countdown.
.