Setting the System

Setting the System (the A Key)

To set the system the user must first enter their code, then press the A key.
This initiates the setting of all parts of the system assigned to that user code.
Once the setting has been initiated the keypad displays the exit time count-
down; at the end of the exit time, or when a Final or Push-to-Set zone terminates
the setting procedure, the Horn outputs and the keypad buzzers become silent
for four seconds, the countdown blocks on the keypad display all clear. The
Horn outputs and keypad buzzers then emit two long tones to confirm that the
system is set. On the keypad the message
before the display clears, see Figure 4.2 Setting Routine.
Note: If the Instant Key 0 option is used to terminate the setting then no
confirmation beeps are given. See
Parameters; 6 User Options; 6 Instant Key 0
TIMED
000000000
000000000
000000000
000000000
000000000
(a)
Exit Time countdown
SYSTEM IS SET
(c)
System Set confirmation
The following points should be noted:
• If the code has all parts assigned then a full set takes place. This means
that in the event of an alarm condition Bell, Strobe and Intruder outputs
activate, the Galaxy 16 plus, if programmed, also signals to the ARC.
Note: The activation of the Bell, Strobe and Intruder outputs in part set mode is
programmable. The Bell and Strobe outputs are enabled by default, the
Intruder outputs (for part set) are disabled by default, for more information
see
Section 5: MENU OPTIONS
• If the code does not have all parts assigned, but those parts not
assigned to the code are set, then performing a set results in a full set.
• If the code does not have all parts assigned, and those parts not
assigned
perform a full set. This is in effect a part set, setting of all parts assigned
to the user code; for information on part sets see
System (the B Key)
060
Figure 4.2 Setting Routine.
;
Option 6 – Parameters
to the code are unset, then performing a set will not
.
38
SYSTEM IS SET
appears briefly
Section 5: MENU OPTIONS: 6 –
for details.
TIMED
00000000000000000
00000000000000000
00000000000000000
00000000000000000
00000000000000000
(b)
Countdown terminated
(d)
Screen goes blank
Part Setting the
.