12 AC Fail Delay
When enabled there is a 10 minute delay between the occurrence of an a.c.
mains failure and activation of the AC Fail outputs. If the a.c. mains is restored
before output activation then no output activation occurs. This avoids
signalling of false or short term a.c. mains failures.
13 Zone Restoral
When enabled this attribute records the closing (–) of Exit, Intruder and Dual
zones in the Event Log. This will also signal these events via SIA communica-
tions format.
14 User 13 Duress
When enabled this attribute assigns a Duress function to User Code 13. Entry
of this code will cause a Duress alarm which activates the PA outputs (but not
Horn, Intruder, Bell, Strobe).
15 Rem When Set
When disabled (default) this function restricts remote access to when the
system is unset.
When the system is either Set, or Part-set, then remote or local servicing by
Galaxy Gold via a Telecoms module or an RS232 is inhibited until such time as
the system becomes fully Unset. If the system is set and the engineer tries to
dial into the site, a connection is still made but once the connection is made the
Galaxy Gold keypad display is blank and pressing keys on the Galaxy Gold
keypad has no effect. The Galaxy Gold keypad remains in this inactive state
until the system is fully Unset. If the system is Full-set or Part-set while the
engineer is connected to the site, the Galaxy Gold keypad becomes inactive
until the system is fully unset. The engineer may, at any time during the Galaxy
Gold Keypad inactivity, terminate the connection to the system using the pull-
down menu (Connect/Hang-up).
When enabled this function allows Remote servicing even when the system is
Set.

07 Reset

This parameter is used to determine which alarms require a system reset.
There are four reset types:
• When the Intruder and PA reset parameters are enabled they can be reset
by a user code with the Code Reset attribute enabled or the Engineer Code
(Usr 15). Disabling this parameter means that any code can reset an Intruder
or PA activation.
• When the Tamper reset parameter is enabled it requires to be reset by the
Engineer Code (Usr 15). Disabling this allows it to be reset by a user code
with the Code Reset parameter enabled.
6 = Parameters (cont'd)
63