■Memory switch setting screen
No.
①②
Network offline setting
Network connection validity/invalidity is selected.
: Network connection is enabled.
: Network connection is prohibited.
③④
Clock correction function
Clock correction validity/invalidity when there is network connection is set up.
: Clock correction is not enabled.
: The panel clock is corrected in reference to the host PC clock when there is net-
work connection.
⑤⑥
Remaining buffer for ISS measurement warning
Warning (E205) is generated when the ISS measurement data capacity stored in the panel
becomes small.
: No warning is generated.
: A warning (E205) is generated when the data capacity to output to the network is
becoming small (if this warning is generated even when the system is connected
to the network, there may be a problem in network connection).
: A warning is generated when the data capacity to output to USB thumb drive is
becoming small. Insert a USB memory in the panel and output data if this warning
is generated.
* It is strongly recommended to select the last one to gather data by means of the
USB thumb drive instead of connecting the operation panel to the network.
⑦⑧
Backlight off setting
These keys are used to change over the backlight off setting.
: The backlight is automatically turned off.
: The backlight status is changed over between on/off by means of the backlight switch.
⑨⑩
Backlight off time setting
This item should be set in the case the backlight automatic-off is selected.
: With this switch, the time to be elapsed until the backlight is automatically turned
off is set. (Unit: Second)
4) After the completion of the aforementioned setting, press switch ❸ . Then, the screen is changed over to
the information screen.
Description
– 77 –
Initial value
10.0