Item
00 Number of sttches
Sets the number of sttches to be sewn at the begnnng of sewng
sewn before thread
before the thread clamp solenod (CN3-) starts operatng
clamp works at
0 :
the begnnng of
-9 : The number of sttches to be sewn before the thread clamp
sewng
03 Needle cooler
Delay tme from the stop of sewng machne to the output OFF s
output OFF delay
specified using the needle cooler output function.
tme
20 Man shaft
Man shaft reference angle s compensated.
reference angle
compensaton
2 Up poston
Angle to detect UP poston startng s compensated.
startng angle
compensaton
22 DOWN poston
Angle to detect DOWN poston startng s compensated.
startng angle
compensaton
24 Settng of energy-
Settng to reduce the power consumpton whle the sewng machne
savng functon
s n standby state
durng standby
0: Energy-savng mode s neffectve
: Energy-savng mode s effectve
* do not change the set values with asterisk (*) mark as they are functions for maintenance. If the standard set value set at the
time of delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated.
If it is necessary to change the set value, please purchase the Engineer's Manual and follow the instructions.
Descrpton
Thread clamp solenod does not operate.
solenod operates
Settng range
– 44 –
Indcaton of functon settng
N-GAST
0-9
(sttches)
T-DNCOFF
00 to to
2000 ms
A-ZDET
–0 to 0
A-UDET
–5 to 5
A-DDET
–5 to 5
F-PSAVE
0/