How to Programme the Low Ha...
1-24 Motor Current
Range:
Size
related
10000.00 A]
*
NOTE
This parameter cannot be changed while the motor is
running.
1-25 Motor Nominal Speed
Range:
6
6
Size related
*
RPM]
NOTE
This parameter cannot be changed while the motor is
running.
5-12 Terminal 27 Digital Input
Option: Function:
Select the function from the available digital input
range.
No operation
Reset
Coast inverse
Coast and reset inverse
Quick stop inverse
DC-brake inverse
Stop inverse
Start
Latched start
Reversing
Start reversing
Enable start forward
Enable start reverse
Jog
Preset ref bit 0
Preset ref bit 1
Preset ref bit 2
Freeze reference
Freeze output
Speed up
Speed down
Set-up select bit 0
Set-up select bit 1
Catch up
68
Function:
[
0.10 -
Enter the nominal motor current
value from the motor nameplate
data. This data is used for
calculating motor torque, motor
thermal protection etc.
Function:
[100 - 60000
Enter the nominal motor speed
value from the motor nameplate
data. This data is used for
calculating automatic motor
compensations.
MG34O202 - VLT
VLT Automation Low Harmonic Drive Operating Instructions
5-12 Terminal 27 Digital Input
Option: Function:
1-29 Automatic Motor Adaptation (AMA)
Option:
[0]
[1]
[0]
OFF
*
[1]
Enable
[2]
complete
[3]
AMA
[4]
[5]
[6]
[8]
[9]
[10]
[11]
[2]
Enable
[12]
reduced
[13]
AMA
[14]
[16]
Note:
[17]
•
[18]
[19]
•
[20]
[21]
[22]
•
[23]
[24]
[28]
®
is a registered Danfoss trademark
Slow down
Pulse input
Ramp bit 0
Ramp bit 1
Mains failure inverse
DigiPot Increase
DigiPot Decrease
DigiPot Clear
Reset Counter A
Reset Counter B
Table 6.1
Function:
The AMA function optimizes dynamic motor
performance by automatically optimizing the
advanced motor parameters (parameters 1-30
to 1-35) at motor standstill.
Activate the AMA function by pressing [Hand
on] after selecting [1] or [2]. See also the
section Automatic Motor Adaptation. After a
normal sequence, the display will read: "Press
[OK] to finish AMA". After pressing the [OK]
key the frequency converter is ready for
operation.
This parameter cannot be adjusted while the
motor is running.
Performs AMA of the stator resistance R
rotor resistance R
, the stator leakage
r
reactance X
, the rotor leakage reactance X
1
and the main reactance X
FC 301: The complete AMA does not include
X
measurement for FC 301. Instead, the X
h
value is determined from the motor database.
Par. 1-35 may be adjusted to obtain optimal
start performance.
Performs a reduced AMA of the stator
resistance R
in the system only. Select this
s
option if an LC filter is used between the drive
and the motor.
For the best adaptation of the frequency
converter, run AMA on a cold motor.
AMA cannot be performed while the motor is
running.
AMA cannot be performed on permanent magnet
motors.
[29]
[32]
[34]
[35]
[36]
[55]
[56]
[57]
[62]
[65]
, the
S
2
.
h
h