Digital In/Out; Comm. And Options - Danfoss VLT AutomationDrive FC 300 Operating Instructions Manual

Low harmonic drive
Hide thumbs Also See for VLT AutomationDrive FC 300:
Hello, I am your AI assistant. How can I help you?
Table of Contents

Advertisement

How to Programme the Low Ha...

6.4.2 Digital In/Out 5-**

Par.
Parameter description
No. #
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
6
6
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-16
Terminal X30/2 Digital Input
5-17
Terminal X30/3 Digital Input
5-18
Terminal X30/4 Digital Input
5-19
Terminal 37 Safe Stop
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
5-31
Terminal 29 Digital Output
5-4* Relays
5-40
Function Relay
5-41
On Delay, Relay
5-42
Off Delay, Relay
Table 6.49

6.4.3 Comm. and Options 8-**

Par.
Parameter description
No. #
8-0* General Settings
8-01
Control Site
8-02
Control Word Source
8-03
Control Word Timeout Time
8-04
Control Word Timeout Function
8-05
End-of-Timeout Function
8-06
Reset Control Word Timeout
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
FC Port Baud Rate
8-35
Minimum Response Delay
8-36
Max Response Delay
8-37
Max Inter-Char Delay
8-5* Digital/Bus
8-53
Start Select
8-55
Set-up Select
Table 6.50
126
VLT Automation Low Harmonic Drive Operating Instructions
Default value
[0] PNP
[0] Input
[0] Input
[8] Start
[0] No operation
[0] No operation
[0] No operation
[90] AC Contactor
[91] DC Contactor
[0] No operation
[0] No operation
[0] No operation
[1] Safe Stop Alarm
[0] No operation
[0] No operation
[0] No operation
0.30 s
0.30 s
Default value
[0] Digital and ctrl.word
null
1.0 s
[0] Off
[1] Resume set-up
[0] Do not reset
[1] FC MC
2 N/A
[2] 9600 Baud
10 ms
5000 ms
25 ms
[3] Logic OR
[3] Logic OR
®
MG34O202 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion
index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
Conver-
Type
sion
index
-
Uint8
-
Uint8
-1
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-3
Uint16
-3
Uint16
-3
Uint16
-
Uint8
-
Uint8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 300 and is the answer not in the manual?

Questions and answers

Table of Contents