Configuring Ptz Limit Stops - HIKVISION E SERIES User Manual

Network speed dome
Hide thumbs Also See for E SERIES:
Table of Contents

Advertisement

User Manual of E Series Network Speed Dome
Power-off Memory: The dome can resume its previous PTZ status or actions after it restarted
from a power-off. You can set the time point of which the dome resumes its PTZ status. You
can set it to resume the status of 30 seconds, 60 seconds, 300 seconds or 600 seconds before
power-off.
3. Click
to save the settings.
5.3 Configuring PTZ Limits
Purpose:
The dome can be programmed to move within the configurable PTZ limits (left/right, up/down).
Steps:
1.
Enter the Limit Configuration interface:
Configuration > Advanced Configuration > PTZ > Limit
2.
Click the checkbox of Enable Limit and choose the limit type as manual stops or scan stops.
Manual Stops:
When manual limit stops are set, you can operate the PTZ control panel manually only in the
limited surveillance area.
Scan Stops:
When scan limit stops are set, the random scan, frame scan, auto scan, tilt scan, panorama
scan is performed only in the limited surveillance area.
Manual Stops of Limit Type is prior to Scan Stops. When you set these two limit
types at the same time, Manual Stops is valid and Scan Stops is invalid.
3.
Click the PTZ control buttons to find the left/right/up/down limit stops; you can also call the
defined presets and set them as the limits of the dome.
4.
Click Set to save the limits or click Clear to clear the limits.
© Hikvision
Figure 5-3 Configure the PTZ Limit