API Commands
TYPE
EXECUTION
SYNTAX
DESCRIPTION
The Trigger On (
of the Set Trigger Configuration (
source and follows the same rules as other trigger sources as defined by the
valid only when an acquisition is configured where either the start and/or stop event is defined as the Trigger On
command. If this command is issued when the acquisition is not configured for stop and/or start Trigger On
command, an error condition will occur.
EXAMPLE
PRINT#1, "OUTPUT07;T1,1,0,0X"
PRINT#1, "OUTPUT07; @X"
SLEEP 10
PRINT#1, "OUTPUT07; @X"
A-12

- Trigger On Command

@
Acquisition
Deferred
Trigger upon receipt of an
@
) command will start or stop the acquisition accordingly when the
@
) command is set to
T
@
start
(trigger on). The
command is used as a trigger
1
T
command. The
T
' Configure an acquisition with both start and stop
trigger being Trigger On command
' Start the acquisition
' Wait 10 seconds to collect data
' Stop the acquisition
Appendix A
or
arguments
stop
command is
@
ChartScan User's Manual