6.17 MOdIFyING ThE TRANSMISSION UNIT

Should two pellet stoves of the same model be installed close to each other and the remote control beam activates both simultaneously, it is possible
to modify the transmission unit when the stove has been shut down by taking the following steps:
Function
Open the flap and press the SET and OPT keys simultaneously. Using
Select UNIT function
the SELECT MENU key choose one of the eight transmission units (0÷7).
Standard setting on pellet stoves is 0.
Disconnect the power cable. Reconnect it and within five seconds press
the ON/OFF key, keeping it pressed down for approx. 3 - 4 seconds.
Restart stove
An audible beep indicates the successful change of unit.
Two display pages will appear in sequence while the remote control will
return to the initial display.
a
Unit storage remains as set even without batteries.

6.18 'MULTIFUOCO SySTEM' OPERATION

The appliance with "Multifuoco System" is equipped with two fans overseeing hot air diffusion.
This provision enables multiple channeled hot air diffusion solutions, allowing the user freedom of choice depending on adjacent rooms to be heated.
Below, you will find a general and concise description of the operation of the Multifuoco System supplied.
It is possible to set the "Multifuoco System" according to four speeds to match fan operation to the channeling solution selected.
These speeds are represented by the values 01, 02, 03, 04 which appear in the row under the display and small rectangles numbered from 1 to 4
in the row above.
When switching from speed 01 to speed 04, the fan air flow increases.
Once the speed of the Multifuoco System has been set, it is possible to select a higher or lower heat quantity by selecting from the five appliance
power levels: P1, ..., P5.
In the same way, more heat is provided by the appliance when switching from power P1 to power P5.
It is left to the user, based upon their own experience of using the appliance, to set the Multifuoco speed and the appliance power.
These selections should be based upon the channeling distance and the desired heating temperatures (by way of example, the longer the channeling
route, the higher the set speed of the Multifuoco System).
To select the desired Multifuoco value, see the paragraph "START-UP AND STANDARD OPERATION".
52
SELECT UNIT
Action
H07028420 / DT2000990 – 01
DT2010248-04
Display
S E L E C T
S E L E C T
S E L E C T
U N I T
2
U N I T
2
U N I T
2
S E A R C H
S E A R C H
S E A R C H
F I E L D
F I E L D
F I E L D
U N I T
2
U N I T
2
U N I T
2
L O A D E D
L O A D E D
L O A D E D
1
1
1
DT2040072-05
DT2012379-00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip 78/58

Table of Contents