5.2 CONvECTIvE AIR OUTLET POSITIONS

To ensure correct flow and disposal of convective air inside the installation area, we recommend that you strictly respect the:
- safety distances;
- insert distance and position relative to the housing and subsequent cladding;
- dimensions of outlets and minimum sections required for inflow and outflow of the convective air (See paragraph "TECHNICAL SPECIFICATIONS");
- the implementation and respect for measurements and sections of the external air intake (See paragraph "TECHNICAL SPECIFICATIONS").
a
The convective air outlets must not be confused with the external air intake.
The convective air outlets serve to dispatch the heat inside the cladding or housing and cool the product components.
The external air intake serves to provide the appliance with combustive air.
These outlets may or may not be equipped with non-reclosable grille and must respect the minimum section needed specified in
paragraph "TECHNICAL SPECIFICATIONS".
The convective air outflow from inside the housing is achieved by inserting a grille (H) to the hood to the position indicated in the diagram.
The convective air inflow inside the housing is achieved via various solutions:
(1) implement an outlet in the back part (example A – outlet P);
(2) implement an outlet in the back part or on the left or right side (example A - outlet G) provided that the insert does not rest against a closed base
and the relative optional support is used.
a
Failure to respect such conditions may affect correct air flow and consequently, the safety of the product.
ACCEPTED SOLUTIONS FOR CONVECTIVE AIR INFLOW AND OUTFLOW POSITIONS.
Fig. 35
A
132 min
(6)(a)
142 min
(6)(b)
10
9,5
N.
Description
6
Minimum distance between the upper part of the insert and the infill or ceiling inside the supporting wall.
7
MINIMUM measurements for supporting wall INLET hole.
8
MINIMUM supporting wall INLET hole height in the instance of installation of pellet drawer kit.
9
Minimum position of the hood grille of the upper insert part.
G
Side convective air inlet.
H
Hood grille (convective air outlet).
P
Back convective air inlet.
P
P
2
G
H07028420 / DT2000990 – 01
H
40 min
(9)
65
(8)(a)
59
(7)(a)
75
(8)(b)
69
(7)(b)
79
(7)
38
G
DT2012280-00
Measurements in cm
(a) = IP 78/58
(b) = IP 78/68
DT2033612-01