In line with its policy of constant product improvement and renewal, the manufacturer may make changes without notice. This document is the property of Gruppo Piazzetta S.p.A.; no part of it may be disclosed to third parties without the written permission of Gruppo Piazzetta S.p.A.
Dimensional diagram with pellet drawer kit H 64 Dimensional diagram with support kit Dimensional diagram with pellet loading kit Dimensional diagram with additional pellet tan k kit 2.10 Wiring diagram IP 78/58 - IP 78/68 FUEL PREPARING FOR INSTALLATION INSTALLATION Position of insert in housing and cladding...
1.0 GENERAL RULES DT2010216-05 Ensure that the installation of your product conforms to all the indications given below. Fig. 1 CHIMNEY STACK SINGLE FLUEWAY OR CHIMNEY CONNECTION TO FLUE HOOD GRILLE FLUEWAY LINING WALL SAFETY DISTANCES SOOT INSPECTION APERTURE ELECTRIC POWER SUPPLY LEDGE PROTECTION FRESH AIR...
Ø If the flue pipe is an incorrect size or installed other than in Deposit of creosote compliance with the above instructions, Gruppo Piazzetta S.p.A. cannot be held liable for malfunctioning of the product, DT2030050-00 DT2030188-00 damage to property or injury to persons or animals.
DT2010025-03 1.3 ChIMNEy STACk The chimney stack is a device fitted on the top of the chimney that is designed to Fig. 7 Fig. 8 aid dispersion of the products of combustion in the atmosphere. The chimney stack must comply with the following requirements: - it must have an internal section and shape the same as the flue (A);...
DT2010539-03 1.4 FRESh AIR INTAkE To ensure trouble-free operation the stove/firebox must have the Fig. 12 necessary air available for combustion and this is provided through the fresh air intake. The fresh air intake must: HOOD - have a total free cross section at least equal to the size given in the GRILLE paragraph “TECHNICAL DATA”;...
Gas appliances of type B are not allowed (refer to current legislation and regulations in the place of installation). The stove or firebox must not be used simultaneously with collective type ventilation ducts with or without extractor fan, other devices or other appliances such as: forced ventilation systems or other heating systems using ventilation to change the air. Such systems could cause a vacuum in the environment of installation even if installed in adjoining or communicating rooms.
DT2012404-00 1.9 MINIMUM SAFETy dISTANCES Walls Fig. 15 FLAMMABLE WALLS: the installation of the appliance next to flammable walls P is only permitted where suitable insulation and non-combustible protective material is used. In order to insulate the appliance and correctly install the cladding, construct a supporting wall made of non-flammable material (e.g.
Area surrounding the chimney Fig. 18 Where the flooring surrounding the firebox is made of flammable material, you must protect it using NON-FLAMMABLE materials, or it must be replaced with flooring made of non-flammable material. Below, we will demonstrate how to identify this area. • The flooring in the area in front of the firebox “A”, must be covered up to a distance equal to the height “H”...
Page 11
It must also permit periodic cleaning of the flue without the need to disassemble the pipes. This type of fitting can be bought at Piazzetta retail outlets together with the pipes.
150mm. It is also recommended that you insulate the chimney flue (Fig. 21-22). Pipes and bends made by Gruppo Piazzetta S.p.A. are recommended WITH DAMAGED FLUE for connection to the flueway, since they are sized to fit the flue outlet of the appliance.
DT2010232-02 1.12 USING AN ExTERNAL FLUE An external flue can be used provided it complies with the following Fig. 23 requirements: - use only insulated stainless steel pipes (double-lined) fixed to the outside wall of the building (Fig. 23); - there must be an inspection opening at the base of the flue to permit periodic checks and maintenance;...
Cladding: ......in enamelled steel Interior: ......in steel Baffle plate and hearth: ..in cast iron Grate: .......IP 78/58: in steel; IP 78/68: in cast iron Door: ........in cast iron with ceramic glass heat resistant up to 750°C Handle: ......concealed painted steel Control panel: ....remote control with LCD and emergency keys on the appliance...
Pellet loading kit: can cope with a total capacity of: - 20 kg per IP 78/58* Optional - 29 kg per IP 78/68* Additional pellet tank kit with front loading: can cope with a total capacity of: - 42 kg per IP 78/58...
2.6 dIMENSIONAL dIAGRAM wITh PELLET dRAwER kIT h 64 Fig. 29 36,5 Ø 8 32,5 50,5 (a) = IP 78/58 (b) = IP 78/68 Dimensions in cm DT2033586-01 2.7 dIMENSIONAL dIAGRAM wITh SUPPORT kIT Fig. 30 74,5 32,5 Ø 8...
DT2033593-01 2.10 wIRING dIAGRAM IP 78/58 - IP 78/68 Fig. 33 FUN1 SCAM. SPEED FUN1 SPEED FUN2 FUN2 Pos. Key to parts Pos. Key to parts N° Key to colours Left room fan External thermostat (normally open) White Right room fan...
- inefficient combustion. recommend that you use high-quality pellets. Gruppo Piazzetta S.p.A has tested and programmed its stoves and Pellets should be stored in a sheltered, dry place. can ensure best performance and trouble-free operation using...
With reference to the safety standards in force overseeing electrical appliances, in the instance of all installation, maintenance or intervention operations, which involve accessing the inside of the cladding or smoke box, you must seek the assistance of a Piazzetta Technical Support Centre or qualified personnel.
(4)(a) (4)(b) Measurements in cm (a) = IP 78/58 - SCP 9 (b) = IP 78/68 DT2033610-01 Description Minimum side space, with product extracted, to enable installation, disassembly. Minimum side space, with product extracted, to enable access to electrical parts (without dissembling the entire product).
(8)(b) (7)(b) Measurements in cm (a) = IP 78/58 (b) = IP 78/68 DT2033612-01 Description Minimum distance between the upper part of the insert and the infill or ceiling inside the supporting wall. MINIMUM measurements for supporting wall INLET hole.
DT2012464-00 5.3 MULTIFUOCO SySTEM • Thanks to Piazzetta technology and R&D, this pellet appliance offers Fig. 36 the advantages of the “Multifuoco system”, a system EXCLUSIVE to and PATENTED by Gruppo Piazzetta S.p.A. Brand new within the pellet heat generator sector.
Hot air outlet radiation area (mm) - Fig. 43 Fig. 43 HOT AIR OUTLET VENT An area where the presence of flammable objects (furniture, carpets, curtains, etc.) or those affected by heat (wood, plastic,...) are forbidden is to be provided around the hot air outlet. The following figure displays the measurements relative to the safety area;...
- position the base in the installation housing, respecting the positioning Fig. 46 measurements with respect to the extractable part of the product (Fig. 46); - check the flatness of the base, insert suitable shims where required; - where required, carry out Multifuoco channeling of the left fan, refer to the paragraph “MULTIFUOCO SYSTEM”...
Pressure plug (5) Fig. 49 • The appliance is equipped with an external plug to measure the smoke outlet duct vacuum. This management and checking operation must be carried out by authorised persons upon installing the firebox or when carrying out maintenance (Fig. 49). DB9 serial port (6) • The appliance is equipped with a DB9 serial port used to carry out checks on appliance operation.
DT2012096-00 5.7 ASSEMbLy OF ExTRACTAbLE PART Now proceed with the final operations before installation is complete. Fig. 51 Subsequent to a further check on what has been completed up to this point, proceed as follows: - COMPLETELY extract the sliding rails present on the base; - insert the lifting handle provided into the respective housings present on both sides of the extractable part;...
Page 29
To secure the base [E] to the support [B] use the screws and washers [C Fig. 53 and D] supplied with the support. (Fig. 53-54) With regards handling of the product, follow the instructions detailed in the paragraph FIXING THE BASE. DT2033260-00 Fig.
6.0 USE DT2010992-00 • Do not use the stove as a cooking appliance. • Ensure that the room in which the stove is installed is sufficiently well ventilated (fresh air intake). • Ensure that all joints in the flue are hermetically sealed using a silicone- (not cement-) based sealant which is resistant to temperatures of up to 250ºC and which shows no sign of deterioration.
If the stove is not receiving signals from the remote try bringing the remote closer to the stove. Below are listed the various functions of the remote control’s keys. GRUPPO PIAZZETTA MENU DT2030325-00 NUMBER...
DT2010082-07 6.3 LIGhTING FOR ThE FIRST TIME • Before lighting the stove for the first time, check that the grate is properly placed. • There will be odours when lighting the first few times due to the evaporation of paints and oils used during the manufacturing process. During this stage, air the room well where the stove is installed and avoid staying there any length of time since the fumes being given off could be harmful to persons or pets.
DT2010151-00 6.4 STARTUP ANd NORMAL OPERATION • Before proceeding with lighting the stove: Fig. 59 C O N T R O L Ensure that the hearth door is well closed. O F F • Check that the pellet tank is full or at least contains enough pellets for the stove to run for the desired period.
Page 34
C L E A N I N G 1 2 : 0 0 2 6 programmed by Gruppo Piazzetta personnel. B R A Z I E R B R A Z I E R This procedure removes ash deposits and other buildups, which would otherwise prevent correct stove operation.
Page 35
SHUTDOWN C L E A N I N G Action Description Display B R A Z I E R Hold the ON/OFF key 1 2 : 0 0 2 2 down for several C L E A N I N G Fuel loading stops, while the cooling fan and the extractor fan continue to seconds operate until the stove has cooled.
DT2012309-00 6.5 TROUbLEShOOTING A list of situations that could occur and instructions on what to do is given below. FAILED IGNITION Description Display The stove is in the startup phase, the readout “NO LIT” appears on the display and the warning buzzer sounds (if set).
Page 37
RESTARTING DURING THE SHUTDOWN PHASE Description Display SITUATION 1 The stove is in the shutdown phase and the readout CLEANING BRAZIER is on the display. W A I T The stove is restarted by the user pressing the ON/OFF key. C O O L I N G The readout “WAIT COOLING”...
DT2012075-00 6.6 CONTROL PANEL The appliance boasts an emergency device with 2 buttons and an LED, Fig. 60 positioned on the bottom right of the door; using this, it is possible to control the appliance in the instance where the remote control with LCD display is not functioning.
DT2012020-01 6.8 PROGRAMMING The remote control can be used to select the following functions from the main MENU: • SELECT LANGUAGE LANGUAGE ITALIANO Remote control LANGUAGE PORTUGUES LANGUAGE FRANCAIS LANGUAGE ENGLISH MENU LANGUAGE ESPANOL LANGUAGE NEDERLAND LANGUAGE DEUTSCH • SET CLOCK DAY MONDAY DAY TUESDAY DAY WEDNESDAY...
DT2011296-00 6.9 PROGRAMMING ThE CLOCk The stove leaves the factory with the clock already set. All that needs to be done, therefore, is to check that the time is precise or if any change is needed because of summer time. Correct time setting is necessary to be able to use all the functions where time is involved.
DT2010242-05 6.10 TIMER The timer allows the user to programme the stove to start up and shut down automatically without any manual intervention. Daily, weekly and weekend programmes can be selected with a maximum of two operating cycles in two separate timetable bands. For example: Cycle 1: from 6am until 9am.
Page 42
C H R O N O C H R O N O C H R O N O C H R O N O P R O G R A M P R O G R A M P R O G R A M C H R O N O C H R O N O P R O G R A M...
Page 43
WEEK PROGRAMME Function Action Display S E T S E T S E T S E T Select set chrono Press the MENU key. Using the SELECT MENU key select the SET CHRONO S E T S E T C H R O N O S E T C H R O N O menu...
Page 44
Function Action Display S E T S E T S E T S E T S E T S E T S E T S E T Set desired power for Press SELECT MENU to set the desired power (for example you want C H R O N O C H R O N O P O W E R...
Page 45
Function Action Display S E T E N A B L E S E T E N A B L E Press the SELECT MENU key and select ON to enable the weekend S E T E N A B L E S E T E N A B L E S E T...
Function Action Display S E T E N A B L E S E T S E T E N A B L E S E T Set desired Press SELECT MENU to set the desired fan speed (for example, you want Multifuoco fan speed C H R O N O W E E K E N D...
DT2010256-00 6.12 MULTICOMFORT The pellet stove is fitted with the Multicomfort function. This works in conjunction with the Multifuoco ventilation system to improve heat distribution. It allows the room temperature to be read from the stove or from the remote control, so that the Multifuoco settings can be varied according to the requirements of the rooms to be heated.
Page 48
The operating principle is as follows: When the room temperature measured by the remote control or the stove reaches the temperature value programmed by the user, the stove automatically goes to power level 1 (readout “OK” on the display). If the room temperature continues to rise with operation at power level 1 up to the value set on the STOP function (e.g. + 2°C compared to the programmed temperature), the stove shuts down and goes into the stand-by mode.
DT2011866-00 6.14 PARAMETER MENU The User can only interact with the LOADING AUGER and MEMORY COUNTERS in the parameter menu, as described in the table below. The other parameters can only be used by an authorised service centre. LOADING AUGER When the stove is new or the pellets have been completely used up, prior to startup and ignition, carry out the LOADING AUGER function.
Page 50
HOUR COUNTER MEMORY Function Action M E N U Display M E N U M E N U P A R A M E T E R M E N U P A R A M E T E R M E N U P A R A M E T E R M E N U...
DT2040065-03 6.15 ENAbLE bEEP (AUdIO SIGNAL) This function allows you to engage or disengage the alarm signal emitted by the stove to indicate that it has received the remote control’s commands. ENABLE BEEP (audio signal) Function Action Display E N A B L E E N A B L E Select enable beep Press the MENU key.
DT2010248-04 6.17 MOdIFyING ThE TRANSMISSION UNIT Should two pellet stoves of the same model be installed close to each other and the remote control beam activates both simultaneously, it is possible to modify the transmission unit when the stove has been shut down by taking the following steps: SELECT UNIT Function Action...
DT2012313-00 6.19 SAFETy dEvICES During operation some parts of the stove (door, handle, ceramic parts) can reach high temperatures. Remember to maintain the safety distances indicated previously. Be careful, take all due precautions and always comply with the instructions. If during operation smoke leaks from any part of the stove or the flue, shut the stove down immediately and ventilate the room. When the stove has cooled, check for the cause of the leak and if necessary call in specialist personnel.
Page 54
FLUE GAS TEMPERATURE SENSOR Description Display A sensor positioned at the flue gas outlet and connected to the PCB constantly monitors the working temperature allowing the stove to be used in all safety. S A F E T Y The readout “SAFETY STOVE” appears on the display. If the flue gas temperature exceeds the fixed safety limit, the power supply to the fuel-loading auger S T O V E is cut off thus depriving the grate of pellets and starting the stove shutdown process.
STOVE ROOM TEMPERATURE SENSOR Description Display A sensor is connected to the rear of the stove; it constantly monitors the temperature in the immediate vicinity of the stove to ensure that it can be operated in all safety. The symbol “00” appears on the display in place of the room temperature. L E V E L It means that the sensor has been momentarily disconnected or accidentally dislodged.
DT2012118-00 6.21 INSERT ExTRACTION The IP pellet insert is designed so that it can be extracted “like a drawer” Fig. 62 so that it is possible to access the back of the appliance to carry out maintenance and/or repair operations. The product is equipped with a safety system which stops accidental movements.
DT2012365-00 Pursuant to current regulations on the safety of electrical equipment, you must contact a Piazzetta Group After-Sales Service Centre or a qualified electrician for all and any work connected with installation, maintenance or servicing that involves access inside the cladding or the smoke chamber.
DT2012367-00 7.2 CLEANING ThE COMbUSTION ChAMbER Once a week, clean the combustion chamber as follows: Fig. 67 - remove the brazier; - rotate the cams forward so that they free up the internal deflector; - gently lift it to release it from the bottom slot, rotate it bringing the top part outwards and extract it;...
The stove is fitted with a 4 mm thick glass panel, resistant to thermal shock up to 750°C; the glass can only be broken by heavy impact or misuse. Do not slam the door or hit the window. In case of breakage replace only with a Gruppo Piazzetta spare part. To replace, proceed as follows: - wear protective gloves;...
The fans must therefore be cleaned, at least, once a year. As this operation involves dismantling some parts of the appliance, only call upon the assistance of a Piazzetta Technical Support Centre or qualified personnel to clean the fans. DT2010096-04 7.9 whEN NOT IN USE...
It is therefore recommended that only “Gruppo Piazzetta S.p.A.” authorised Service Centres be contacted. Whenever authorised Service Centre personnel carry out work, they must show an identity card issued by Gruppo Piazzetta S.p.A. on which the following are printed: name of the Service Centre, stamp and signature of the company and the period of validity of the actual document.
Page 62
Replace the pressure switch (use only Faulty pressure switch “ALF 2” stove status original spares) Check the electrical connections (contact a Piazzetta After-Sales No power supply to the auger Service Centre or an authorised person) Thermal cutout “ALC” stove status...
Page 63
Pellet-charging system blocked clean the auger and chute This instruction booklet contains all the necessary information for installation, operation and maintenance. Only call the Gruppo Piazzetta S.p.A. service centre after having scrupulously followed all the instructions. H07028420 / DT2000990 – 01...
DT2012380-01 8.1 REPLACING ThE FUSES Electronic board fuse. Fig. 71 Unscrew the cartridge fuse or safety plug from the electronic board and replace with a similar one. Fuse rating “S” on motherboard R: F4AL250V. DT2033405-01 EUROPEAN REGULATIONS DT2010382-05 This product “IP” with Multicomfort has been designed, tested and manufactured according to the European R&TTE Directives 1999/5/EC. Following these Directives, this product can be installed in the following countries: (BE) Belgium...
DICHIARAZIONE DI CONFORMITA’ DECLARATION OF CONFORMITY Il sottoscritto, rappresentante il seguente costruttore The undersigned, representative of the following manufacturer Gruppo Piazzetta S.p.A. Via Montello, 22 31010 Casella D’Asolo (TV) – ITALY DICHIARA che l’apparecchiatura descritta in appresso: DECLARES that the product:...
Page 68
Product serial number, to be quoted when requesting service from the Gruppo Piazzetta After-Sales Service Centre. Via Montello, 22 31011 Casella d’Asolo (TV) - ITALY Tel. +39.04235271 - Fax +39.042355178 www.piazzetta.it e-mail:infopiazzetta@piazzetta.it...
Need help?
Do you have a question about the IP 78/68 and is the answer not in the manual?