Electric Power Supply; Prevention Of Domestic Fires; Technical Characteristics And Specifications; Features - Piazzetta IP 78/68 Instructions For Installation, Use And Maintenance Manual

Pellet inserts
Table of Contents

Advertisement

1.15 ELECTRIC POwER SUPPLy

Make sure there is a power socket 230V 50Hz in the rear appliance wall and a switch on the outside of the cladding to be able to cut off the power
supply during maintenance or when the appliance is not being used.
The installation must be earthed and fitted with a circuit breaker in accordance with current wiring regulations.
a
When connected ensure that the power cable does not come into contact with hot parts.

1.16 PREvENTION OF dOMESTIC FIRES

The product must be installed and used in compliance with the manufacturer's instructions and European and national standards as well as local
regulations.
a
When a flue pipe passes through a wall or a ceiling, special installation methods must be applied (protection, thermal insulation,
distances from heat-sensitive materials, etc.) See the paragraph "CONNECTING TO A CONVENTIONAL CHIMNEY".
• It is also recommended that all elements made of combustible or inflammable material, such as beams, wooden furniture, curtaining, flammable
liquids, etc. be kept outside the heat radiation range of the stove and at a distance of at least 80 cm from the heating block.
• For other information, see the paragraph "MINIMUM SAFETY DISTANCES" and "CONNECTING TO A CONVENTIONAL CHIMNEY".
• The flue pipe, chimney stack, chimney and fresh air intake must always be free of obstructions, clean and checked periodically, that is, at least
twice during the seasonal period from the lighting of the stove and during its use. When the stove has not been used for some time it is advisable
to carry out the checks mentioned above. For further information, consult a chimneysweep.
• Only use recommended fuels (See section "FUEL").

2.0 TEChNICAL ChARACTERISTICS ANd SPECIFICATIONS

2.1 FEATURES

Cladding: ..........................in enamelled steel
Interior: .............................in steel
Baffle plate and hearth: .....in cast iron
Grate: ...............................IP 78/58: in steel; IP 78/68: in cast iron
Door: ................................in cast iron with ceramic glass heat resistant up to 750°C
Handle: .............................concealed painted steel
Control panel: ...................remote control with LCD and emergency keys on the appliance
Timer thermostat: .............standard with daily, weekly and weekend programming modes divided into two time bands
Power setting: ...................from 1 to 5
Ash drawer: ......................removable
Fuel: .................................natural pure wood pellets (see section "FUEL")
Heating: ............................Multifuoco System forced ventilation with two fans and option of separate operation, four fan settings, option of operation
with remote control displayed room temperature setting (see section "MULTICOMFORT"). Two bottom-up front hot air
outlets. Option, upon request, of a back outlet for channeling of the left fan (see section "MULTIFUOCO SYSTEM").
14
H07028420 / DT2000990 – 01
DT2010179-01
DT2010027-02
DT2012050-00
DT2010990-00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip 78/58

Table of Contents