Hot air outlet radiation area (mm) - Fig. 43
An area where the presence of flammable objects (furniture, carpets,
curtains, etc.) or those affected by heat (wood, plastic,...) are forbidden
is to be provided around the hot air outlet.
The following figure displays the measurements relative to the safety
area; this area includes the 600 mm taken into account starting at the
upper edge of the outlet.
a
Where there is flammable flooring, the hot air outlets must be
placed at a distance of at least 200 mm from the floor.
5.4 FIxING ThE bASE
The appliance is formed of two parts, one sliding, the other fixed, on
which all other connections are carried out: smoke outlet, electrical
connection, Multifuoco channeling and external thermostat.
After having fully unpackaged the product, proceed as follows:
- remove the flange nuts [A], two on each side, present on the product
(Fig. 44);
- open the door, release the mobile part of the product (see chapter
"USE" paragraphs "OPENING DOOR" and "PELLET LOADING") and
carefully allow it to slide forward approximately 5-10 cm;
- insert the lifting handle [B] provided into the respective housings [C]
present on both sides (Fig. 45);
- separate the two parts and CAREFULLY lay the sliding part on the
ground;
Fig. 43
Fig. 44
A
Fig. 45
B
H07028420 / DT2000990 – 01
HOT AIR OUTLET VENT
600
600
C
DT2030172-00
DT2012092-00
A
DT2033010-00
B
DT2033011-00
25