Modifying The Transmission Unit; Multifuoco' System Operation - Piazzetta P960 Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

6.17 MOdIFyING ThE TRANSMISSION UNIT

Should two pellet stoves of the same model be installed close to each other and the remote control beam activates both simultaneously, it is possible
to modify the transmission unit when the stove has been shut down by taking the following steps:
Function
Open the flap and press the SET and OPT keys simultaneously. Using the
Select UNIT function
SELECT MENU key choose one of the eight transmission units (0 - 8).
Standard setting on pellet stoves is 0.
Disconnect the power cable. Reconnect it and within five seconds press
the ON/OFF key, keeping it pressed down for approx. 3 - 4 seconds.
Restart stove
An audible beep indicates the successful change of unit.
Two display pages will appear in sequence while the remote control will
return to the initial display.
a
Unit storage remains as set even without batteries.

6.18 'MULTIFUOCO' SySTEM OPERATION

The pellet stove with 'Multifuoco System' is fitted with one/two fans for the circulation of hot air according to the model.
This system allows several solutions for the distribution of ducted hot air, so that the user has freedom of choice as regards the number of adjoining
rooms which can be heated.
Operation of the 'Multifuoco System' will be explained in general and conceptual terms below.
In order to adjust the fan to suit the chosen ducting solution, four 'Multifuoco System' speed settings have been pre-programmed, which appear
as 01, 02, 03, 04 in the bottom line of the display and as small rectangles from 1 to 4 in the top line.
There is a greater volume of air transferred by the fan passing from speed setting 01 to 04.
Once the 'Multifuoco System' speed has been set, the user can choose a higher or lower amount of heat by selecting one of the five power settings
on the stove: P1, ..., P5.
Similarly, there is a greater quantity of hot air produced by the stove passing from power setting P1 to P5.
It is at the user's discretion, based upon experience and familiarity in using the product, which of the 'Multifuoco' speed settings and which power
level to choose.
These choices will be based on the length of the ducting and the required room temperature (as an indication, the longer the ducting the higher the
Multifuoco System speed setting).
For each of the solutions described in the INSTALLATION section under "MULTIFUOCO SYSTEM", there is a specific Multifuoco fan setting
recommended.
If opting for SOLUTION 1, it is best to use the control panel to select the speed setting "01".
If opting for SOLUTION 2, a higher fan speed will be required, in which case for the fan connected to the long duct the speed setting on the control
panel shall not be lower than "02".
Finally, if opting for SOLUTION 3 or SOLUTION 4, an even higher fan speed will be required, in which case it would be best to select the speed setting
"03" or "04" on the control panel.
To select the required Multifuoco setting, refer to the paragraph "NORMAL OPERATION".
48
SELECT UNIT
Action
H07028100/DT2000970 – 01
DT2010248-04
Display
S E L E C T
S E L E C T
S E L E C T
U N I T
2
U N I T
2
U N I T
2
S E A R C H
S E A R C H
S E A R C H
F I E L D
F I E L D
F I E L D
U N I T
2
U N I T
2
U N I T
2
L O A D E D
L O A D E D
L O A D E D
1
1
1
DT2040072-05
DT2010231-04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P961P962

Table of Contents