• Connecting the lambda sensor.
Connect the lambda sensor connector by placing the cable between relay cables
as shown in the picture.
Place the lambda sensor connector between the two relays and the high voltage
coil as shown in the picture.
Arrange the fuel pump cable as shown.
Connect the fuel pump connector and place it at the level of the generator/pick-
up and G.P.S. sensor connectors.
Part. N. 8000 B0148 (02-2008)
ELECTRIC SYSTEM, DIGITAL INSTRUMENT
M.55
Lamda probe
connector
Fuel pump
cable
Clamp
Fuel pump
connector
Lamda probe
cable
Sensor
connector