18
. IGNITION SYSTEM
MXU 500
IGNITION PULSE GENERATOR
INSPECTION
Disconnect the ignition pulse generator
connector.
Measure the ignition pulse generator resistance
between the Green/White wire and Blue/Yellow
wire.
Standard: 791
(20ºC/68ºF)
Ignition Pulse Generator Connector
IGNITION COIL
REMOVAL/INSTALLATION
Disconnect the spark plug cap from the spark
plug (page 18-4).
Disconnect the ignition coil primary connectors.
Remove the two bolts and the ignition coil.
Installation is in the reverse order of removal.
Ignition Coil
IGNITION CONTROL MODULE
Ignition Control Module
REMOVAL/INSTALLATION
Remove the seat (refer to the "FRAME
COVERS" section in the chapter 2).
Disconnect the ignition control module
connectors and remove the ignition control
module.
18-6