Setting Of Timer Counter Mode Register - NEC PD754144 User Manual

4-bit single-chip microcontrollers
Table of Contents

Advertisement

Address
7
F90H
Remark When the timer counter (channel 2) is used as the PWM pulse generator mode, set the operation mode
select bits TM10 and TM11 of the time counter (channel 1) to 0.
146
CHAPTER 6 PERIPHERAL HARDWARE FUNCTION
Figure 6-36. Setting of Timer Counter Mode Register
6
5
4
3
TM26
TM25
TM24
TM23
Count pulse (CP) select bit
TM26
TM25
TM24
0
1
0
f
/2
X
0
1
1
f
X
10
1
0
0
f
/2
X
8
1
0
1
f
/2
X
6
1
1
0
f
/2
X
4
1
1
1
f
/2
X
Other
Setting prohibited
Timer start command bit
Clears counter and IRQT2 flag when "1" is written. Starts count operation
TM23
if bit 2 is set to "1".
Operation mode
TM22
0
Stops (count value retained)
1
Count operation
Operation mode select bit
TM21
TM20
0
1
PWM pulse generator mode
User's Manual U10676EJ3V0UM
2
1
0
Symbol
TM22
TM21
TM20
TM2
Count pulse (CP)
Count operation
Mode