BATTERY
The battery mounted on this motorcycle is a sealed
battery therefore no maintenance is required.
The following battery is used: KOYO KTZ-10S
This is a sealed battery with breather valve. No elec-
trolyte level checking is required.
Never remove the battery seal caps nor block
the breather opening.
CHARGING THE BATTERY
Charge the battery using the current and charging time
shown on the battery itself.
To avoid overcharging the battery, we recommend
using the constant voltage charging method as speci-
fied in the table below:
Method
V
C
(voltage) (temperature) (charging current)
Normal
14,4
20
Fast
14,4
20
Should the engine fail to start, charge the battery again
using the same amperage and the same charging
time.
Overcharging the battery or charging it rapidly may
lower the level of the electrolyte, thus making the bat-
tery unusable.
Voltages lower than 11.8V shorten the life
NOTE
and impair the operation of the battery.
Checking stored batteries once a month pro-
longs their life while keeping them in perfect
working order for future use.
Electrical system
A
Charging time
(hours)
0,25xC
12-24
1xC
6-8
- 7 -