Wireless Settings Page - AMX MVP-5200i-GB Instruction Manual

Table of Contents

Advertisement

System Settings Page
Back:
WiFi/Wired/USB Icon:
Connection Status Icon: The icon in the upper-right corner of each Protected Setup page provides a constant visual indication of current
Master Connection:
Type:
Mode:
System Number:
Master IP/URL:
Master Port Number:
Username/Password: If the target Master has been previously secured, enter the username assigned to a pre-configured user profile
Password:
USB IP Settings:
Refer to the Ethernet Over USB section on page 34 for more detailed information on using the System Settings page.

Wireless Settings Page

Use the options on the Wireless Settings page (FIG. 60) to configure communication settings for the wireless CF card (802.11b/g),
and read the device number assigned to the panel.
Wireless Settings page (reads from and assigns values to the AP)
FIG. 60
Features on this page include:
Wireless Settings Page
Back:
WiFi/Wired/USB Icon:
Connection Status
Icon:
MVP-5200i Modero® ViewPoint® Touch Panel with Intercom - Instruction Manual
Saves all changes and returns to the previous page.
The icon to the left of the Connection Status Icon displays whether the current connection to the Master is
Wireless (image of a radio antenna), Wired (image of three networked computers), or USB (USB connection
symbol).
connection status.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx Master.
Sets the NetLinx Master communication values:
Displays how the panel is connected to the Master. The connection may be Wireless (wireless connection) or Any
(no connection). This field cannot be changed.
Cycles between the connection modes: URL, Listen, and Auto.
• Auto - In this mode, enter the System Number and a username/password (if applicable). Use this mode when
both the panel and the NetLinx Master are on the same Subnet and the Master has its UDP feature enabled.
The Master IP/URL field is read-only.
• URL - In this mode, enter the IP/URL, Master Port Number, and username/password (if used) on the Master.
The System Number field is read-only - the panel obtains this information from the Master.
• Listen - In this mode, add the panel address into the URL List in NetLinx Studio and set the connection mode
to Listen. This mode allows the Modero touch panel to "listen" for the Master's communication signals. The
System Number and Master IP/URL fields are read-only.
Allows entry of a system number. Default value is 0 (zero). (Enabled in Auto Mode Only.)
Sets the Master IP or URL of the NetLinx Master. (Enabled in URL Mode Only.)
Allows entry of the port number used with the NetLinx Master. Default = 1319
on the Master. This profile should have the pre-defined level of access/configuration rights.
If the target Master has been previously secured, enter the password assigned to a pre-configured user profile
on the Master. This profile should have the pre-defined level of access/configuration rights.
A USB connection is a direct connection from the panel's mini-USB port to a corresponding USB port on the PC
(acting as a Virtual Master). Press either of the fields to open the IP Address and Subnet Mask keypads.
Saves all changes and returns to the previous page.
The icon to the left of the Connection Status Icon displays whether the current connection to the Master is
Wireless (image of a radio antenna), Wired (image of three networked computers), or USB (USB connection
symbol).
The icon in the upper-right corner of each Protected Setup page provides a constant visual indication of current
connection status.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx Master.