Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PE1
4. Ceiling Type S-50PT2E5×2 / U-100PE1E8
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION
TOTAL W
O
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
O
Pdsign
L
Erp
SEER
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
COOL
m
3
/min (ft
I/D AIR
FLOW
3
HEAT
m
/min (ft
3
O/D AIR
COOL
m
/min (ft
FLOW
HEAT
m
3
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-50PT2E5×2
-
ø, Hz
1ø 50Hz
V
220
230
kW
10.0
10.0
34100
34100
A
0.39×2
0.38×2
W
40×2
40×2
-
4
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
37/33/29
55/51/47
dB-A
kW
11.2
11.2
38200
38200
A
0.39×2
0.38×2
W
40×2
40×2
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
37/33/29
55/51/47
dB-A
-
-
0.39×2/40×2 0.38×2/40×2 0.37×2/40×2
-
-
-
43
L/h(Pt/h)
6.0
(3.0×2)
Pa
-
3
/min)
15×2
3
/min)
15×2
3
/min)
3
/min)
235
960
690
360
1025
820
27
34
9 (10)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
U-100PE1E8
CZ-P155BK1
ISO5151 / EN14825
3ø 50Hz
240
380
400
10.0
34100
0.37×2
3.95
3.75
40×2
2.450k
2.450k
2.530k
2.530k
-
1265
-
3.95
3.95 / A
-
-
10.0
-
-
6.4
-
-
547
-
-
A++
-
94
94
52/-
69/-
11.2
38200
0.37×2
4.05
3.85
40×2
2.520k
2.520k
2.600k
2.600k
-
4.31
4.31 / A
-
-
10.0
-
-
-10
-
-
4.3
-
-
3256
-
-
A+
-
95
94
52/-
69/-
-
9.0/5.63k
9.0/5.86k
-
4.05/3.0k
3.85/3.0k
90×2
(12.6)
(530)×2
(530)×2
110
95
R410A
3.40k
9-1/4
1416 55-3/4
37-25/32
940 37-1/32
27-5/32
340 13-13/32
1556
1055
485
(60)
98
(75)
108
1 (2)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 75
(16.4 ~ 246.1)
(49.2/98.4)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-85
-
415
Min
3.3
11300
3.65
-
2.450k
-
2.530k
840
-
-
3.95
3.93
-
-
-
-
93
-
4.1
14000
3.75
-
2.520k
-
2.600k
900
4.31
4.56
-
-
-
-
-
93
-
-
-
9.0/6.02k
3.75/3.0k
-
-
(3885)
(3355)
(119.9)
(216)
(238)
~
1
Max
12.5
42700
-
-
3.850k
-
3.25
-
14.0
47800
-
-
4.400k
3.18
-
/
/
/
/
/
/
/
/
/
~