Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PE1
4. Ceiling Type S-60PT2E5×2 / U-125PE1E8
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION
TOTAL W
O
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
O
Pdsign
L
Erp
SEER
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
COOL
m
3
/min (ft
I/D AIR
FLOW
3
HEAT
m
/min (ft
3
O/D AIR
COOL
m
/min (ft
FLOW
HEAT
m
3
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-60PT2E5×2
-
ø, Hz
1ø 50Hz
V
220
230
kW
12.5
12.5
42700
42700
A
0.42×2
0.41×2
W
50×2
50×2
-
4
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
38/34/30
56/52/48
dB-A
kW
14.0
14.0
47800
47800
A
0.42×2
0.41×2
W
50×2
50×2
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
38/34/30
56/52/48
dB-A
-
-
0.42×2/50×2 0.41×2/50×2 0.40×2/50×2
-
-
-
74
L/h(Pt/h)
7.9
(3.95×2)
Pa
-
3
/min)
20×2
3
/min)
20×2
3
/min)
3
/min)
235
1275
690
360
1340
820
33
42
9 (10)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
U-125PE1E8
CZ-P155BK1
ISO5151 / EN14825
3ø 50Hz
240
380
400
12.5
42700
0.40×2
5.85
5.55
50×2
3.630k
3.630k
3.730k
3.730k
-
1865
-
3.35
3.35 / A
-
-
-
-
-
-
-
-
-
-
-
-
-
94
94
53/-
70/-
14.0
47800
0.40×2
5.50
5.25
50×2
3.410k
3.410k
3.510k
3.510k
-
3.99
3.99 / A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
94
94
-
-
53/-
70/-
-
10.0/6.19k
10.0/6.51k
-
5.85/3.0k
5.55/3.0k
-
90×2
(16.6)
-
(706)×2
(706)×2
130
110
R410A
3.40k
9-1/4
1416 55-3/4
50-3/16
940 37-1/32
27-5/32
340 13-13/32
1556
1055
485
(73)
98
(93)
108
1 (2)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 75
(16.4 ~ 246.1)
(49.2/98.4)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-87
415
Min
Max
3.3
14.0
11300
47800
5.35
-
-
3.630k
-
-
3.730k
840
4.860k
-
-
-
3.35
3.93
2.88
-
-
-
-
94
-
-
4.1
14.0
14000
54600
5.05
-
-
3.410k
-
-
3.510k
900
5.210k
3.99
4.56
3.07
-
-
-
-
-
94
-
-
10.0/6.75k
5.35/3.0k
(4591)
(3885)
(119.9)
/
/
/
/
/
/
/
(216)
/
(238)
/
~
~