Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PE1
6. Low Silhouette Ducted Type S-50PF1E5×2 / U-100PE1E8
INDOOR
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION
TOTAL W
O
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
O
Pdsign
L
Erp
SEER
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
I/D AIR
COOL
m
/min (ft
FLOW
HEAT
m
3
/min (ft
3
O/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Cool O.D(DBT)
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-50PF1E5×2
ø, Hz
1ø 50Hz
V
220
230
kW
10.0
10.0
34100
34100
A
0.77×2
0.74×2
W
100×2
100×2
-
4
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
34/30/26
56/52/48
dB-A
kW
11.2
11.2
38200
38200
A
0.77×2
0.74×2
W
100×2
100×2
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
34/30/26
56/52/48
dB-A
-
-
1.00×2/125×2 0.96×2/125×2 0.92×2/125×2
-
-
-
120
L/h(Pt/h)
6.0
(3.0×2)
Pa
70 (MIN10 - MAX150)
3
/min)
16×2
3
/min)
16×2
3
/min)
3
/min)
290 (11-13/32)
800 (31-1/2)
700 (27-9/16)
355
1014
850
28 (62)
35 (78)
9 (10)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
U-100PE1E8
CZ-P155BK1
ISO5151 / EN14825
3ø 50Hz
240
380
400
10.0
34100
0.71×2
3.68
3.53
100×2
2.245k
2.245k
2.445k
2.445k
-
1222.5
-
4.09
4.09 / A
-
-
10.0
-
-
5.7
-
-
614
-
-
A+
-
93
92
52/-
69/-
11.2
38200
0.71×2
3.86
3.70
100×2
2.400k
2.400k
2.600k
2.600k
-
4.31
4.31 / A
-
-
10.0
-
-
-10
-
-
3.8
-
-
3684
-
-
A
-
94
94
-
-
52/-
69/-
-
9.0/5.550k
9.0/5.850k
-
3.86/3.0k
3.70/3.0k
-
90x2
(12.6)
-
(565)×2
(565)×2
110
95
R410A
3.40k
1416 (55-3/4)
940 (37-1/32)
340 (13-13/32)
1556
1055
485
98
108
1 (2)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 75
(16.4 ~ 246.1)
(49.2/98.4)
50
(537.6)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-131
415
Min
Max
3.3
12.5
11300
42700
3.43
-
-
2.245k
-
-
2.445k
840
3.700k
-
-
-
4.09
3.93
3.38
-
-
-
-
91
-
-
4.1
14.0
14000
47800
3.58
-
-
2.400k
-
-
2.600k
900
4.400k
4.31
4.56
3.18
-
-
-
-
-
93
-
-
9.0/6.100k
3.58/3.0k
(3885)
(3355)
(119.9)
/
/
/
/
/
/
/
/
/
~
~
1