Panasonic S-36PK1E5 Installation Instructions Manual
Panasonic S-36PK1E5 Installation Instructions Manual

Panasonic S-36PK1E5 Installation Instructions Manual

Single split

Advertisement

INSTALLATION INSTRUCTIONS

– Single Split Air Conditioner –
for Refrigerant R410A
■ R410A Models
Model No.
Indoor Units
Indoor
36
Unit Type
Wall
K1
S-36PK1E5 S-45PK1E5 S-50PK1E5 S-60PK1E5 S-71PK1E5
Mounted
ENGLISH
Read through the Installation Instructions before you proceed with the installation.
In particular, you will need to read under the "IMPORTANT!" section at the top of the page.
FRANÇAIS
Lisez les instructions d'installation avant de commencer l'installation.
En particulier, vous devez lire la section "IMPORTANT!" en haut de la plage.
ESPAÑOL
Lea las Instrucciones de instalación antes de proceder con la instalación del equipo.
En concreto, deberá leer detenidamente la sección "¡IMPORTANTE!" situada al principio de la página.
DEUTSCH
Lesen Sie die Einbauanleitung, bevor Sie mit der Installation beginnen.
Insbesondere die Hinweise im Abschnitt "WICHTIG!" oben auf der Seite müssen unbedingt gelesen werden.
ITALIANO
Leggere le Istruzioni di installazione prima di procedere con l'installazione.
Prestare particolare attenzione alla sezione "IMPORTANTE!" all'inizio della pagina.
NEDERLANDS
Lees de installatie-instructies zorgvuldig door voor u begint met de installatie.
U moet vooral het gedeelte waar "BELANGRIJK!" boven staat heel goed lezen.
PORTUGUÊS
Leia cuidadosamente as instruções de instalação antes de prosseguir com a instalação.
Em particular, é necessário ler as informações na secção "IMPORTANTE!" na parte superior da página.
ΕΛΛΗΝΙΚΆ
Διαβάστε τις Οδηγίες εγκατάστασης πριν συνεχίσετε με την εγκατάσταση.
Συγκεκριμένα, θα χρειαστεί να διαβάσετε την ενότητα «ΣΗΜΑΝΤΙΚΟ!» στο πάνω μέρος της σελίδας.
БЪЛГАРСКИ
Прочетете инструкциите за инсталиране преди да продължите с инсталирането.
В частност, ще трябва да прочетете раздела „ВАЖНО!" в горната част на страницата.
РУССКИЙ
Перед выполнением установки прочтите инструкцию по установке.
В частности, вам следует прочесть раздел «ВАЖНО!» вверху страницы.
УКРАЇНСЬКА
Перш ніж продовжити встановлення, прочитайте вказівки зі встановлення.
Зокрема, обов'язково прочитайте розділ «ВАЖЛИВО!» вгорі сторінки.
85464369582012
45
50
60
71
CV6233198798

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic S-36PK1E5

  • Page 1: Installation Instructions

    Indoor Units Indoor Unit Type Wall S-36PK1E5 S-45PK1E5 S-50PK1E5 S-60PK1E5 S-71PK1E5 Mounted ENGLISH Read through the Installation Instructions before you proceed with the installation. In particular, you will need to read under the “IMPORTANT!” section at the top of the page.
  • Page 2: Important

    IMPORTANT! When Transporting Please Read Before Starting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees This air conditioner must be installed by the sales dealer when lifting to reduce strain on your back. Sharp edges or installer.
  • Page 3 • Do not leak refrigerant while piping work for an installation or re-installation, and while repairing refrigeration parts. Handle liquid refrigerant carefully as it may cause frostbite. When Servicing • Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.
  • Page 4: Table Of Contents

    CONTENTS Page Page IMPORTANT! ........2 7.
  • Page 5: General

    1. GENERAL Table 1-1 (Wall Mounted) Part Name Figure Q’ty This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of Truss-head instructions for the indoor and outdoor units and make sure all Phillips Tapping screw accessory parts listed are with the system before beginning.
  • Page 6: Selecting The Installation Site

    2. SELECTING THE INSTALLATION SITE Wall Mounted 2-1. Indoor Unit AVOID: min. 7.5 cm ● areas where leakage of flammable gas may be expected. min. min. 5 cm ● places where large amounts of oil mist exist. 5 cm ● direct sunlight. ●...
  • Page 7: How To Install The Indoor Unit

    3. HOW TO INSTALL THE INDOOR UNIT ■ Wall Mounted Type (K1 Type) 3-1. Remove the Rear Panel from the Unit (1) Remove and discard the set screw on the rear panel. (Fig. 3-1) (2) Press the 2 marks on the frame cover and disengage the stationary tabs from the frame.
  • Page 8: Install The Rear Panel On The Wall

    (4) Using a sabre saw, key hole saw or hole-cutting drill N OT E attachment, cut a hole in the wall. See Table 3-1 and Hole should be made at a slight downward slant to the outdoor Fig. 3-7. side. Indoor Outdoor Table 3-1...
  • Page 9: Removing And Installing The Grille

    3-4. Removing and Installing the Grille Front panel Basically, these models can be installed and wired without removing the grille. If access to any internal part is needed, follow the steps as given below. How to remove the grille (1) Open the front panel until it is nearly horizontal, grasp the sections near the front panel arms on both sides, and then remove the panel by pushing the arms towards the outside while pulling the panel towards you.
  • Page 10: Shape The Indoor Side Tubing

    3-5. Shape the Indoor Side Tubing (1) Arrangement of tubing by direction a) Right or left tubing Cut out the corner of the right/left frame with a hacksaw or the like. (Figs. 3-19 and 3-20) Grille b) Right-rear or left-rear tubing In this case, the corner of the frame need not be cut.
  • Page 11: Mounting

    3-7. Mounting (1) To install the indoor unit, mount the indoor unit onto the 3 tabs on the upper part of the rear plate. (2) Hold down the air discharge outlet and press the lower part of the indoor unit until it clicks to securely fasten to the 2 tabs on the lower part of the rear plate.
  • Page 12 ■ Left-side tubing (1) Lead the tubing and drain hose through the wall, allowing sufficient length for connection. Then bend the tubing using a tube bender to make the attachment. (Fig. 3-28) Rear panel (2) Switch the drain hose and drain cap. Hole in wall Switching drain hose and drain cap (a) Locate the drain hose and the drain cap.
  • Page 13: Drain Hose

    To unmount indoor unit (1) Remove the screw cover on the bottom surface. (Fig. 3-34) (2) Fasten the frame to the rear panel using the 2 supplied tapping screws 4 × 10 mm. (Fig. 3-34) (3) Press the 2 marks on the lower part of the indoor unit and unlatch the tabs.
  • Page 14: Electrical Wiring

    4. ELECTRICAL WIRING 4-1. General Precautions on Wiring (1) Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram. (2) Circuit breaker must be incorporated in the fixed wiring in accordance with the wiring regulations.
  • Page 15: Wiring System Diagrams

    4-3. Wiring System Diagrams * 3-phase model connections Indoor unit (No. 1) Power supply Outdoor unit (3-phase) 220 – 240V ~50/60Hz INV unit Power supply Ground Remote 380/400/415V, 3 N~, 50Hz controller Ground Ground Ground Indoor unit * Single-phase model connections (No.
  • Page 16 CAUTION (1) When linking the outdoor units in a network, disconnect the terminal extended from the short plug from all outdoor units except any one of the outdoor units. (When shipping: In shorted condition.) For a system without link (no wiring connection between outdoor units), do not remove the short plug. (2) Do not install the inter-unit control wiring in a way that forms a loop.
  • Page 17 How to connect wiring to the terminal ■ For stranded wiring (1) Cut the wire end with cutting pliers, Stranded wire Special Screw washer then strip the insulation to expose the stranded wiring about 10 mm and Ring pressure tightly twist the wire ends. (Fig. 4-7) Ring pressure terminal terminal...
  • Page 18: How To Process Tubing

    5. HOW TO PROCESS TUBING Caution Before Connecting Tubes Tightly (1) Apply a sealing cap or water-proof tape to prevent dust or The liquid tubing side is connected by a fl are nut, and the gas water from entering the tubes before they are used. tubing side is connected by brazing.
  • Page 19: Insulating The Refrigerant Tubing

    ● For the flare nuts at tubing connections, be sure to use the Flare insulator (supplied) flare nuts that were supplied with the unit, or else flare nuts Insulation tape (white) Flare union (supplied) for R410A (type 2). The refrigerant tubing that is used must be of the correct wall thickness as shown in the table below.
  • Page 20: Finishing The Installation

    5-5. Finishing the Installation Type After finishing insulating and taping over the tubing, use sealing putty to seal off the hole in the wall to prevent rain and draft Period 2 weeks from entering. (Fig. 5-10) Apply putty here N OT E The frequency with which the filter should be cleaned depends on the environment in which the unit is used.
  • Page 21 ■ When Using Wireless Remote Controller Instead of Cleaning the main unit and remote controller Wired Remote Controller ● Wipe clean using a soft, dry cloth. ● To remove stubborn dirt, moisten a cloth in warm water no Wall Mounted (K1 Type) hotter than 40 °C, wring thoroughly, and then wipe.
  • Page 22 ■ Troubleshooting If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. ● Indoor unit Symptom Cause ● Noise Sound like streaming water during Sound of refrigerant liquid flowing inside unit ●...
  • Page 23 ● Check Before Requiring Services Symptom Cause Remedy Air conditioner does not run Power failure or after power failure Press ON/OFF operation button on remote at all although power is turned controller again. ● Operation button is turned off. Switch on power if breaker is turned off. ●...
  • Page 24 ENGLISH Compliance with regulation 842/EC/2006 Article 7(1) requirements DO NOT VENT R410A INTO THE ATMOSPHERE: R410A IS A FLUORINATED GREENHOUSE GAS, COVERED BY THE KYOTO PROTOCOL, WITH A GLOBAL WARMING POTENTIAL (GWP) = 1975. FRANÇAIS Conformité aux exigences de l’article 7 (1) de la réglementation 842/EC/2006 NE PAS METTRE LE R410A À...

This manual is also suitable for:

S-45pk1e5S-50pk1e5S-60pk1e5S-71pk1e5

Table of Contents